Inverter SOLAX X3-HYB-4.0-G4 Pro WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 39,06 kg |
| CN | 85044085 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 39,06 kg |
| CN | 85044085 |
X3-HYB-G4 PRO Hybrid Inverter
The X3-HYB-G4 PRO hybrid inverter is an advanced three-phase solution for residential properties, offering smart energy management, high efficiency, and reliability. With compatibility for V2H technology and a wide MPPT range, it provides flexibility and optimal use of PV power.
Key features of the X3-HYB-G4 PRO:
- 20 A DC input per MPPT with 3 trackers, supports 200% PV overloading and AC output up to 110%.
- Wide MPPT range from 110 to 950 V, with a starting voltage of 120 V.
- Up to 200% EPS output for 10 seconds and UPS-level transfer time <10 ms.
- Dual battery ports with a 2-in-1 function, compatibility with a wireless meter, and a practical cable cover.
- Optional AFCI protection and built-in Type II SPD protection on both AC and DC sides.
- Compatible with VPP (OpenADR, IEEE2030.5, FCAS, API) and features Smart Schedule, Smart Scene, and 24/7 TOU.
Who is this a good choice for?
The X3-HYB-G4 PRO inverter is an ideal choice for single-family homeowners looking for an efficient, intelligent solar energy management system. It performs well in installations that require high reliability, flexible battery connections (up to 800 V), and integration with smart home systems and V2H technology. Its wide MPPT range and ability to handle PV power surpluses make it an excellent solution for homes with large photovoltaic arrays.
| Parameter | X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P |
| PV INPUT | |||||||
| Max PV input voltage | 1000 V | ||||||
| Operating voltage range | 110-950 V | ||||||
| Max recommended PV array power | 8 kWp | 10 kWp | 12 kWp | 16 kWp | 20 kWp | 24 kWp | 30 kWp |
| Rated PV input voltage | 650 V | ||||||
| MPPT® voltage range | 110-950 V | ||||||
| Start-up voltage | 120 V | ||||||
| Number of MPP trackers / strings per tracker | 2 (1/1) | 3 (1/1/1) | |||||
| Max input current per MPPT | 20 A/20 A | 20 A/20 A | 20 A/20 A | 20 A/20 A/20 A | 20 A/20 A/20 A | 20 A/20 A/20 A | 20 A/20 A/20 A |
| Max short-circuit input current per MPPT | 25 A/25 A | 25 A/25 A | 25 A/25 A | 25 A/25 A/25 A | 25 A/25 A/25 A | 25 A/25 A/25 A | 25 A/25 A/25 A |
| AC INPUT AND OUTPUT (GRID-TIED) | |||||||
| Rated output power | 4000 W (AS 4777 4999 W) | 5000 W (AS 4777 4999 W) | 6000 W | 8000 W | 10000 W (AS 4777 9999 W) | 12000 W | 15000 W (AS 4777 14999 W) |
| Rated output current | 5.8 A | 6.7 A | 8.7 A | 11.6 A | 14.5 A | 17.5 A | 21.8 A |
| Max output apparent power | 4400 VA | 5500 VA | 6600 VA | 8800 VA | 11000 VA (AS 4777 9999 VA) | 13200 VA | 16500 VA (AS 4777 14999 VA) |
| Max continuous output current | 6.7 A | 8.4 A | 10.0 A | 13.4 A | 16.8 A | 20.0 A | 25.0 A |
| Rated AC voltage | 3/N/PE, 220/380 V or 230/400 V | ||||||
| Max AC input apparent power | 8.4 kVA | 10.5 kVA | 12.6 kVA | 16.8 kVA | 21.0 kVA | 24.3 kVA | 30.4 kVA |
| Max AC input current | 12.2 A | 15.2 A | 18.2 A | 25.4 A | 30.4 A | 35.2 A | 43.4 A |
| Rated AC frequency | 50 Hz / 60 Hz | ||||||
| AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz | ||||||
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | ||||||
| THDi (Rated Power) | <3% | ||||||
| BATTERY | |||||||
| Battery type | Lithium | ||||||
| Battery voltage range | 130-800 V | ||||||
| Max charge / discharge current | 50 A (25 A × 2) ④ | ||||||
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||||
| Rated output frequency | 400 V/230 V, 50 Hz / 60 Hz | ||||||
| EPS frequency | 400 V/230 V, 50 Hz / 60 Hz | ||||||
| Rated EPS output power | 4 kVA | 5 kVA | 6 kVA | 8 kVA | 10 kVA | 12 kVA | 15 kVA |
| EPS peak output power | 2 times rated power, 10 s | ||||||
| Transfer time | < 10 ms | ||||||
| EFFICIENCY | |||||||
| Max efficiency | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% |
| European efficiency | 97.7% | ||||||
| ENVIRONMENTAL LIMITS | |||||||
| Protection rating | IP66 | ||||||
| Operating ambient temperature range | -35 – 60°C ⑤ | ||||||
| Maximum operating altitude | 3000 m | ||||||
| Relative humidity | 0-100% RH (condensation) | ||||||
| Surge category | Utility: III, Battery: II, PV: II | ||||||
| GENERAL | |||||||
| Dimensions (W x H x D) | 560 x 503 x 210 mm | ||||||
| Net weight | 38 kg | ||||||
| Cooling concept | Natural cooling | Intelligent cooling | |||||
| Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER/CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | ||||||
| Power consumption (night) | <40 W in standby mode, <5 W in idle mode | ||||||
| Topology | Non-isolated | ||||||
| Certifications and approvals | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | ||||||
| PROTECTION | |||||||
| AC auxiliary power supply (APS) | Built-in | ||||||
| Active anti-islanding method | Frequency shifting | ||||||
| Surge protection (DC/AC) | DC: Type II, AC: Type II | ||||||
| Arc-fault circuit interrupter (AFCI) | Optional | ||||||
| Additional protections | Over/under voltage protection, DC insulation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | ||||||
⑤ Reduced value at +45°C