Inverter SOLAX X3-HYB-5.0-G4 Pro WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 38,72 kg |
| CN | 85044085 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | 3 |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | Yes |
| SPD Type II | |
| AFCI | Optional |
| MPPT voltage range | |
| Weight | 38,72 kg |
| CN | 85044085 |
X3-HYB-G4 PRO Hybrid Inverter
The X3-HYB-G4 PRO hybrid inverter is an advanced three-phase solution designed for residential properties, offering intelligent energy management, high efficiency, and reliability. With compatibility with V2H technology and a wide MPPT range, it provides flexibility and optimal use of PV power.
Key features of the X3-HYB-G4 PRO:
- DC input current 20 A per MPPT with 3 trackers, supports 200% PV overloading and AC output up to 110%.
- Wide MPPT range from 110 to 950 V, with a start-up voltage of 120 V.
- Up to 200% EPS output for 10 seconds and UPS-level transfer time <10 ms.
- Dual battery ports with a 2-in-1 function, compatibility with a wireless meter, and a practical cable cover.
- Optional AFCI protection and built-in Type II SPD protection on both AC and DC sides.
- Compatibility with VPP (OpenADR, IEEE2030.5, FCAS, API) and features such as Smart Schedule, Smart Scene, and 24/7 TOU.
Who is this a good choice for?
The X3-HYB-G4 PRO inverter is an ideal choice for single-family homeowners looking for an efficient and intelligent solar energy management system. It suits installations that require high reliability, flexibility in battery connection (up to 800 V), and integration with smart home systems and V2H technology. Its wide MPPT range and ability to handle PV power surpluses make it an excellent solution for homes with large photovoltaic installations.
| Parameter | X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P |
| PV INPUT | |||||||
| Max. PV input voltage | 1000 V | ||||||
| Operating voltage range | 110-950 V | ||||||
| Max. recommended PV array power | 8 kWp | 10 kWp | 12 kWp | 16 kWp | 20 kWp | 24 kWp | 30 kWp |
| Nominal PV input voltage | 650 V | ||||||
| MPPT® voltage range | 110-950 V | ||||||
| Start-up voltage | 120 V | ||||||
| Number of MPP trackers/strings per tracker | 2 (1/1) | 3 (1/1/1) | |||||
| Max. input current per MPPT | 20 A/20 A | 20 A/20 A | 20 A/20 A | 20 A/20 A/20 A | 20 A/20 A/20 A | 20 A/20 A/20 A | 20 A/20 A/20 A |
| Max. short-circuit input current per MPPT | 25 A/25 A | 25 A/25 A | 25 A/25 A | 25 A/25 A/25 A | 25 A/25 A/25 A | 25 A/25 A/25 A | 25 A/25 A/25 A |
| AC INPUT AND OUTPUT (ON-GRID) | |||||||
| Rated output power | 4000 W (AS 4777 4999 W) | 5000 W (AS 4777 4999 W) | 6000 W | 8000 W | 10000 W (AS 4777 9999 W) | 12000 W | 15000 W (AS 4777 14999 W) |
| Rated output current | 5.8 A | 6.7 A | 8.7 A | 11.6 A | 14.5 A | 17.5 A | 21.8 A |
| Max. output apparent power | 4400 VA | 5500 VA | 6600 VA | 8800 VA | 11000 VA (AS 4777 9999 VA) | 13200 VA | 16500 VA (AS 4777 14999 VA) |
| Max. continuous output current | 6.7 A | 8.4 A | 10.0 A | 13.4 A | 16.8 A | 20.0 A | 25.0 A |
| Nominal AC voltage | 3/N/PE, 220/380 V or 230/400 V | ||||||
| Max. AC input apparent power | 8.4 kVA | 10.5 kVA | 12.6 kVA | 16.8 kVA | 21.0 kVA | 24.3 kVA | 30.4 kVA |
| Max. AC input current | 12.2 A | 15.2 A | 18.2 A | 25.4 A | 30.4 A | 35.2 A | 43.4 A |
| Nominal AC frequency | 50 Hz / 60 Hz | ||||||
| AC frequency range® | 50 ± 5 Hz / 60 ± 5 Hz | ||||||
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | ||||||
| THDi (Rated Power) | <3% | ||||||
| BATTERY | |||||||
| Battery type | Lithium | ||||||
| Battery voltage range | 130-800 V | ||||||
| Max. charge/discharge current | 50 A (25 A × 2) ④ | ||||||
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||||
| Rated EPS output voltage/frequency | 400 V/230 V, 50 Hz / 60 Hz | ||||||
| EPS, frequency | 400 V/230 V, 50 Hz / 60 Hz | ||||||
| Rated EPS output power | 4 kVA | 5 kVA | 6 kVA | 8 kVA | 10 kVA | 12 kVA | 15 kVA |
| Peak EPS output power | 2 times rated power, 10 s | ||||||
| Switching time | < 10 ms | ||||||
| EFFICIENCY | |||||||
| Max. efficiency | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% |
| European efficiency | 97.7% | ||||||
| ENVIRONMENTAL LIMITS | |||||||
| Ingress protection | IP66 | ||||||
| Operating ambient temperature range | -35 to 60°C ⑤ | ||||||
| Max. operating altitude | 3000 m | ||||||
| Relative humidity | 0-100% RH (condensing) | ||||||
| Overvoltage category | Mains: III, Battery: II, PV: II | ||||||
| GENERAL | |||||||
| Dimensions (W x H x D) | 560 x 503 x 210 mm | ||||||
| Net weight | 38 kg | ||||||
| Cooling concept | Natural cooling | Intelligent cooling | |||||
| Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER/CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | ||||||
| Power consumption (night) | <40 W in standby mode, <5 W in idle mode | ||||||
| Topology | Non-isolated | ||||||
| Certifications and approvals | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | ||||||
| PROTECTION | |||||||
| AC auxiliary power supply (APS) | Built-in | ||||||
| Active anti-islanding method | Frequency shift | ||||||
| Surge protection (DC/AC) | DC: Type II, AC: Type II | ||||||
| Arc fault circuit interrupter (AFCI) | Optional | ||||||
| Additional protections | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Return current monitoring, residual current detection, Over temperature protection, AC overvoltage protection, AC short-circuit protection | ||||||
⑤ Reduced value at +45°C