Inverter SOLAX X3-HYB-6.0-G4 Pro WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 39,06 kg |
| CN | 85044085 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 39,06 kg |
| CN | 85044085 |
Three-phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO
The three-phase hybrid inverter SolaX Power X3-HYB-G4 PRO is an advanced solution for residential properties, offering intelligent energy management and high efficiency. Available in a wide power range from 4 kW to 15 kW, it supports V2H technology, intelligent scheduling, and compatibility with a wireless meter. With dual battery ports, a wide MPPT range, and the capability for 200% PV oversizing, it’s a flexible and reliable device for maximizing self-consumption.
Key features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:
- Intelligent energy management: V2H compatibility for smart home energy integration, Smart Schedule, Smart Scene, 24/7 TOU, and cooperation with VPP (OpenADR, IEEE2030.5, FCAS, API).
- High performance and PV flexibility: DC input current 20 A per MPPT with 3 trackers, support for 200% PV oversizing, AC output up to 110%, and a very wide MPPT range (110–950 V).
- Assured reliability and safety: Up to 200% EPS output power for 10 seconds, UPS-level transfer time under 10 ms, optional rapid shutdown function, Type II SPD protection on AC and DC sides, and optional AFCI protection.
- Flexible adaptation options: Dual battery ports and a “2-in-1” expansion function, extra ports to simplify wiring, and a functional, stylish cable cover.
- Versatile operating modes: Supports microgrid and generator modes for a variety of applications.
- Performance curve: High efficiency maintained across a wide load range, as demonstrated by the performance curve for the 15 kW model.
Who is this a good choice for?
The SolaX Power X3-HYB-G4 PRO inverter is an excellent choice for single-family homeowners seeking an advanced, efficient, and reliable hybrid system. Its intelligent energy management features, high flexibility in configuring PV arrays and batteries, and extensive safety and adaptation options make it an ideal solution for maximizing self-consumption, providing backup power, and integrating with a smart home. The wide power range allows you to match the system to individual energy needs.
| Parameter | X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P |
|---|---|---|---|---|---|---|---|
| PV INPUT | |||||||
| Max recommended PV array power (kWp) | 8 | 10 | 12 | 16 | 20 | 24 | 30 |
| Max PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Nominal PV input voltage (V) | 650 | 650 | 650 | 650 | 650 | 650 | 650 |
| Operating voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| MPPT voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| Start-up voltage (V) | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| Number of MPP trackers / strings per MPP tracker | 2 (1 / 1) | 2 (1 / 1) | 2 (1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) | 3 (1 / 1 / 1) |
| Max input current per MPPT (MPPT1/2/3) (A) | 20 / 20 | 20 / 20 | 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 | 20 / 20 / 20 |
| Max short-circuit input current per MPPT (MPPT1/2/3) (A) | 25 / 25 | 25 / 25 | 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 | 25 / 25 / 25 |
| AC INPUT AND OUTPUT (GRID-TIED) | |||||||
| Rated output power (W) | 4000 | 5000 (AS 4777 4999 W) | 6000 | 8000 | 10000 (AS 4777 9999 W) | 12000 | 15000 (AS 4777 14999 W) |
| Rated output current (A) | 5.8 | 7.2 | 8.7 | 11.6 | 14.5 | 17.5 | 21.8 |
| Max output apparent power (VA) | 4400 | 5500 (AS 4777 4999 VA) | 6600 | 8800 | 11000 (AS 4777 9999 VA) | 13200 | 16500 (AS 4777 14999 VA) |
| Max continuous output current (A) | 6.7 | 6.7 | 8.4 | 10.0 | 13.4 | 20.0 | 25.0 |
| Nominal AC voltage | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V |
| Max input apparent power AC (kVA) | 8.4 | 10.5 | 12.6 | 16.8 | 21.0 | 21.0 | 21.0 |
| Max AC input current (A) | 12.2 | 15.2 | 18.2 | 24.3 | 30.4 | 30.4 | 30.4 |
| Nominal AC frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| AC frequency range (Hz) | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 | 50 ± 5 / 60 ± 5 |
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
| THDi (Rated Power) (%) | <3 | <3 | <3 | <3 | <3 | <3 | <3 |
| BATTERY | |||||||
| Battery type | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium |
| Battery voltage range (V) | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 |
| Max charge/discharge current (A) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) | 50 (25 x 2) |
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||||
| Nominal EPS output voltage, frequency | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz |
| Rated EPS output power (kVA) | 4 | 5 | 6 | 8 | 10 | 12 | 15 |
| Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
| Transfer time (ms) | < 10 | < 10 | < 10 | < 10 | < 10 | < 10 | < 10 |
| EFFICIENCY | |||||||
| Max efficiency (%) | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 | 98.0 |
| European efficiency (%) | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 | 97.7 |
| ENVIRONMENTAL LIMITS | |||||||
| Protection rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating ambient temperature range (°C) | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 | -35 – 60 |
| Max operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 |
| Relative humidity | 0 – 100% RH (condensation) | 0 – 100% RH (condensation) | 0 – 100% RH (condensation) | 0 – 100% RH (condensation) | 0 – 100% RH (condensation) | 0 – 100% RH (condensation) | 0 – 100% RH (condensation) |
| Overvoltage category | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II |
| GENERAL | |||||||
| Dimensions (W x H x D) (mm) | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 |
| Net weight (kg) | 38 | 38 | 38 | 38 | 38 | 38 | 38 |
| Cooling concept | Natural cooling | Natural cooling | Natural cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
| Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) |
| Power consumption (night) (W) | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Certifications and approvals | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 |
| Auxiliary AC power (APS) | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in |
| PROTECTION | |||||||
| Protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection |
| Active anti-islanding method | Frequency shifting | Frequency shifting | Frequency shifting | Frequency shifting | Frequency shifting | Frequency shifting | Frequency shifting |
| Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
Notes:
① The maximum input voltage is the upper limit of DC voltage. Any DC input voltage above this limit will likely damage the inverter.
② Input voltage outside the MPPT voltage range may trigger inverter protection.
③ The AC frequency range may vary according to different country codes.
④ If each of the two battery ports is connected to a separate battery, the limit is 25 A per port. If one port is connected to a single battery, it is 30 A. If both ports are connected to a single battery using a 2‑in‑1 splitter cable (sold separately), it is 50 A.
⑤ Derating at +45°C.

