Inverter SOLAX X3-Hybrid-12.0-D WiFi + LAN

SKU: F20S13 EAN: 2010000031902
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

RS485

SPD Type II

AFCI

MPPT voltage range

Maksymalny prąd wejściowy na MPPT [A]

Maksymalna moc wejściowa [W]

Weight 36,7 kg
CN 85044086
Price 2 046,63 
Gross

2 046,63 
Gross

In stock:

5 pcs
Login to place an order

2 046,63 
Gross

In stock:

5 pcs
Login to place an order

Datasheet Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Datasheet.pdf Warranty Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Warranty.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

RS485

SPD Type II

AFCI

MPPT voltage range

Maksymalny prąd wejściowy na MPPT [A]

Maksymalna moc wejściowa [W]

Weight 36,7 kg
CN 85044086

Three-phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO

The SolaX Power X3-HYB-G4 PRO hybrid inverter is an advanced three-phase unit designed for residential properties, offering smart energy management and high efficiency. With a power range from 4 kW to 15 kW, compatibility with V2H technology, and advanced safety features, it provides a comprehensive solution for modern photovoltaic systems with energy storage. It ensures reliable power supply and optimal use of solar energy.

Key features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:

  • Intelligent energy management: Compatible with V2H (Vehicle-to-Home) for smart home energy integration; includes Smart Schedule, Smart Scene, 24/7 TOU (Time of Use) support and compatibility with VPP (Virtual Power Plant) and various standards (OpenADR, IEEE2030.5, FCAS, API).
  • High efficiency and PV flexibility: 20 A DC input current on each of the 3 MPPT trackers, support for up to 200% PV overloading, AC output up to 110% of rated power and a very wide MPPT voltage range (110–950 V).
  • Reliable emergency power (EPS): Can supply up to 200% of rated power on the EPS output for 10 seconds and offers very fast switchover to backup power (UPS-level) in under 10 ms.
  • Advanced safety and adaptability: Built-in Type II SPD protection on both AC and DC sides, optional rapid shutdown and optional AFCI protection. Dual battery ports and a “2-in-1” function make expanding the energy storage system easier.
  • Wide power range and high efficiency: Available in models from 4 kW to 15 kW, with maximum efficiency up to 98.0%, ensuring effective energy conversion.

Who is this a good choice for?

The SolaX Power X3-HYB-G4 PRO is an excellent choice for homeowners looking for an advanced, efficient and reliable hybrid system to manage their energy. Its intelligent features—such as V2H and VPP compatibility—high flexibility in configuring both the PV array and storage, extensive safety options and fast emergency power make it ideal for maximizing self-consumption, ensuring energy security and integrating with a modern smart home. The wide range of available power ratings allows precise matching to individual energy needs.

Datasheet Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Datasheet.pdf Warranty Solax X3-HYB-4.0-P - X3-HYB-15.0-P Solax-X3-HYB-4.0-P-X3-HYB-15.0-P-Warranty.pdf

 

 
Parameter X3-HYB-4.0-P X3-HYB-5.0-P X3-HYB-6.0-P X3-HYB-8.0-P X3-HYB-10.0-P X3-HYB-12.0-P X3-HYB-15.0-P
PV INPUT
Max recommended PV array power (kWp) 8 10 12 16 20 24 30
Max PV input voltage (V) 1000 1000 1000 1000 1000 1000 1000
Rated PV input voltage (V) 650 650 650 650 650 650 650
Operating voltage range (V) 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950
MPPT voltage range (V) 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950
Start-up voltage (V) 120 120 120 120 120 120 120
Number of MPP trackers / strings per MPP tracker 2 (1/1) 2 (1/1) 2 (1/1) 3 (1/1/1) 3 (1/1/1) 3 (1/1/1) 3 (1/1/1)
Max input current per MPPT (MPPT1/2/3) (A) 20 A / 20 A 20 A / 20 A 20 A / 20 A 20 A / 20 A / 20 A 20 A / 20 A / 20 A 20 A / 20 A / 20 A 20 A / 20 A / 20 A
Max short-circuit input current per MPPT (MPPT1/2/3) (A) 25 A / 25 A 25 A / 25 A 25 A / 25 A 25 A / 25 A / 25 A 25 A / 25 A / 25 A 25 A / 25 A / 25 A 25 A / 25 A / 25 A
AC INPUT AND OUTPUT (ON GRID)
Rated output power (W) 4000 5000 (AS 4777 4999 W) 6000 8000 10000 (AS 4777 9999 W) 12000 15000 (AS 4777 14999 W)
Rated output current (A) 5.8 7.2 8.7 11.6 14.5 17.5 21.8
Max apparent output power (VA) 4400 5500 (AS 4777 4999 VA) 6600 8800 11000 (AS 4777 9999 VA) 13200 16500 (AS 4777 14999 VA)
Max continuous output current (A) 6.7 6.7 8.4 10.0 13.4 20.0 25.0
Rated AC voltage (V) 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V
Max apparent AC input power (kVA) 8.4 10.5 12.6 16.8 21.0 21.0 21.0
Max AC input current (A) 12.2 15.2 18.2 24.3 30.4 30.4 30.4
Rated AC frequency (Hz) 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
AC frequency range (Hz) 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (Rated Power) (%) <3% <3% <3% <3% <3% <3%
BATTERY
Battery type Lithium Lithium Lithium Lithium Lithium Lithium Lithium
Battery voltage range (V) 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800
Max charge/discharge current (A) 50 A (25 A × 2) 50 A (25 A × 2) 50 A (25 A × 2) 50 A (25 A × 2) 50 A (25 A × 2) 50 A (25 A × 2) 50 A (25 A × 2)
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output voltage, frequency (V, Hz) 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz
Rated EPS output power (kVA) 4 5 6 8 10 12 15
Peak EPS output power (VA) 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Transfer time (ms) <10 <10 <10 <10 <10 <10 <10
PERFORMANCE
Max efficiency (%) 98.0% 98.0% 98.0% 98.0% 98.0% 98.0% 98.0%
European efficiency (%) 97.7% 97.7% 97.7% 97.7% 97.7% 97.7% 97.7%
ENVIRONMENTAL LIMITS
Protection rating IP66 IP66 IP66 IP66 IP66 IP66 IP66
Operating ambient temperature range (°C) -35 – 60°C -35 – 60°C -35 – 60°C -35 – 60°C -35 – 60°C -35 – 60°C -35 – 60°C
Max operating altitude (m) 3000 3000 3000 3000 3000 3000 3000
Relative humidity (%) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing) 0 – 100% RH (condensing)
Overvoltage category Mains: III, Battery: II, PV: II Mains: III, Battery: II, PV: II Mains: III, Battery: II, PV: II Mains: III, Battery: II, PV: II Mains: III, Battery: II, PV: II Mains: III, Battery: II, PV: II Mains: III, Battery: II, PV: II
GENERAL
Dimensions (W x H x D) (mm) 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210
Net weight (kg) 38 38 38 38 38 38 38
Cooling concept Natural cooling Natural cooling Natural cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump)
Power consumption (night) (W) < 40W in standby, < 5W in idle < 40W in standby, < 5W in idle < 40W in standby, < 5W in idle < 40W in standby, < 5W in idle < 40W in standby, < 5W in idle < 40W in standby, < 5W in idle < 40W in standby, < 5W in idle
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21
AC auxiliary power supply (APS) Built-in Built-in Built-in Built-in Built-in Built-in Built-in
PROTECTION
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II
Arc fault circuit interrupter (AFCI) Optional Optional Optional Optional Optional Optional Optional
Other protections Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection

Notes:

  • ① The maximum input voltage is the upper DC voltage limit. Any higher DC input voltage may damage the inverter.
  • ② Input voltage exceeding the MPPT voltage range may trigger inverter protection.
  • ③ The AC frequency range may vary according to different country codes.
  • ④ If each of the two battery ports is connected to a separate battery, it is 25 A per port. If one port is connected to a single battery, it is 30 A. If both ports are connected to a single battery using a 2-in-1 splitter cable (sold separately), it is 50 A.
  • ⑤ Derating at +45°C.

Official distribution