Inverter SOLAX X3-Hybrid-12.0-D WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 36,7 kg |
| CN | 85044086 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 36,7 kg |
| CN | 85044086 |
Three-phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO
The SolaX Power X3-HYB-G4 PRO hybrid inverter is an advanced three-phase unit designed for residential properties, offering smart energy management and high efficiency. With a power range from 4 kW to 15 kW, compatibility with V2H technology, and advanced safety features, it provides a comprehensive solution for modern photovoltaic systems with energy storage. It ensures reliable power supply and optimal use of solar energy.
Key features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:
- Intelligent energy management: Compatible with V2H (Vehicle-to-Home) for smart home energy integration; includes Smart Schedule, Smart Scene, 24/7 TOU (Time of Use) support and compatibility with VPP (Virtual Power Plant) and various standards (OpenADR, IEEE2030.5, FCAS, API).
- High efficiency and PV flexibility: 20 A DC input current on each of the 3 MPPT trackers, support for up to 200% PV overloading, AC output up to 110% of rated power and a very wide MPPT voltage range (110–950 V).
- Reliable emergency power (EPS): Can supply up to 200% of rated power on the EPS output for 10 seconds and offers very fast switchover to backup power (UPS-level) in under 10 ms.
- Advanced safety and adaptability: Built-in Type II SPD protection on both AC and DC sides, optional rapid shutdown and optional AFCI protection. Dual battery ports and a “2-in-1” function make expanding the energy storage system easier.
- Wide power range and high efficiency: Available in models from 4 kW to 15 kW, with maximum efficiency up to 98.0%, ensuring effective energy conversion.
Who is this a good choice for?
The SolaX Power X3-HYB-G4 PRO is an excellent choice for homeowners looking for an advanced, efficient and reliable hybrid system to manage their energy. Its intelligent features—such as V2H and VPP compatibility—high flexibility in configuring both the PV array and storage, extensive safety options and fast emergency power make it ideal for maximizing self-consumption, ensuring energy security and integrating with a modern smart home. The wide range of available power ratings allows precise matching to individual energy needs.
| Parameter | X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P |
|---|---|---|---|---|---|---|---|
| PV INPUT | |||||||
| Max recommended PV array power (kWp) | 8 | 10 | 12 | 16 | 20 | 24 | 30 |
| Max PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Rated PV input voltage (V) | 650 | 650 | 650 | 650 | 650 | 650 | 650 |
| Operating voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| MPPT voltage range (V) | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 | 110 – 950 |
| Start-up voltage (V) | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| Number of MPP trackers / strings per MPP tracker | 2 (1/1) | 2 (1/1) | 2 (1/1) | 3 (1/1/1) | 3 (1/1/1) | 3 (1/1/1) | 3 (1/1/1) |
| Max input current per MPPT (MPPT1/2/3) (A) | 20 A / 20 A | 20 A / 20 A | 20 A / 20 A | 20 A / 20 A / 20 A | 20 A / 20 A / 20 A | 20 A / 20 A / 20 A | 20 A / 20 A / 20 A |
| Max short-circuit input current per MPPT (MPPT1/2/3) (A) | 25 A / 25 A | 25 A / 25 A | 25 A / 25 A | 25 A / 25 A / 25 A | 25 A / 25 A / 25 A | 25 A / 25 A / 25 A | 25 A / 25 A / 25 A |
| AC INPUT AND OUTPUT (ON GRID) | |||||||
| Rated output power (W) | 4000 | 5000 (AS 4777 4999 W) | 6000 | 8000 | 10000 (AS 4777 9999 W) | 12000 | 15000 (AS 4777 14999 W) |
| Rated output current (A) | 5.8 | 7.2 | 8.7 | 11.6 | 14.5 | 17.5 | 21.8 |
| Max apparent output power (VA) | 4400 | 5500 (AS 4777 4999 VA) | 6600 | 8800 | 11000 (AS 4777 9999 VA) | 13200 | 16500 (AS 4777 14999 VA) |
| Max continuous output current (A) | 6.7 | 6.7 | 8.4 | 10.0 | 13.4 | 20.0 | 25.0 |
| Rated AC voltage (V) | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V | 3/N/PE, 220/380 V; 3/N/PE, 230/400 V |
| Max apparent AC input power (kVA) | 8.4 | 10.5 | 12.6 | 16.8 | 21.0 | 21.0 | 21.0 |
| Max AC input current (A) | 12.2 | 15.2 | 18.2 | 24.3 | 30.4 | 30.4 | 30.4 |
| Rated AC frequency (Hz) | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| AC frequency range (Hz) | 50 ± 5 Hz / 60 ± 5 Hz | 50 ± 5 Hz / 60 ± 5 Hz | 50 ± 5 Hz / 60 ± 5 Hz | 50 ± 5 Hz / 60 ± 5 Hz | 50 ± 5 Hz / 60 ± 5 Hz | 50 ± 5 Hz / 60 ± 5 Hz | 50 ± 5 Hz / 60 ± 5 Hz |
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
| THDi (Rated Power) (%) | <3% | <3% | <3% | <3% | <3% | <3% | |
| BATTERY | |||||||
| Battery type | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium | Lithium |
| Battery voltage range (V) | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 | 130 – 800 |
| Max charge/discharge current (A) | 50 A (25 A × 2) | 50 A (25 A × 2) | 50 A (25 A × 2) | 50 A (25 A × 2) | 50 A (25 A × 2) | 50 A (25 A × 2) | 50 A (25 A × 2) |
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||||
| Rated EPS output voltage, frequency (V, Hz) | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz | 400 V / 230 V, 50 Hz / 60 Hz |
| Rated EPS output power (kVA) | 4 | 5 | 6 | 8 | 10 | 12 | 15 |
| Peak EPS output power (VA) | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
| Transfer time (ms) | <10 | <10 | <10 | <10 | <10 | <10 | <10 |
| PERFORMANCE | |||||||
| Max efficiency (%) | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% |
| European efficiency (%) | 97.7% | 97.7% | 97.7% | 97.7% | 97.7% | 97.7% | 97.7% |
| ENVIRONMENTAL LIMITS | |||||||
| Protection rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating ambient temperature range (°C) | -35 – 60°C | -35 – 60°C | -35 – 60°C | -35 – 60°C | -35 – 60°C | -35 – 60°C | -35 – 60°C |
| Max operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 |
| Relative humidity (%) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) | 0 – 100% RH (condensing) |
| Overvoltage category | Mains: III, Battery: II, PV: II | Mains: III, Battery: II, PV: II | Mains: III, Battery: II, PV: II | Mains: III, Battery: II, PV: II | Mains: III, Battery: II, PV: II | Mains: III, Battery: II, PV: II | Mains: III, Battery: II, PV: II |
| GENERAL | |||||||
| Dimensions (W x H x D) (mm) | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 | 560 x 503 x 210 |
| Net weight (kg) | 38 | 38 | 38 | 38 | 38 | 38 | 38 |
| Cooling concept | Natural cooling | Natural cooling | Natural cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
| Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat pump) |
| Power consumption (night) (W) | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle | < 40W in standby, < 5W in idle |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Certifications and approvals | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 |
| AC auxiliary power supply (APS) | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in | Built-in |
| PROTECTION | |||||||
| Active anti-islanding method | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
| Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
| Other protections | Over/under voltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Backfeed current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short-circuit protection | ||||||
Notes:
- ① The maximum input voltage is the upper DC voltage limit. Any higher DC input voltage may damage the inverter.
- ② Input voltage exceeding the MPPT voltage range may trigger inverter protection.
- ③ The AC frequency range may vary according to different country codes.
- ④ If each of the two battery ports is connected to a separate battery, it is 25 A per port. If one port is connected to a single battery, it is 30 A. If both ports are connected to a single battery using a 2-in-1 splitter cable (sold separately), it is 50 A.
- ⑤ Derating at +45°C.