SOLAX X3-Hybrid-5.0-D Inverter WiFi + LAN
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 35,2 kg |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maksymalny prąd wejściowy na MPPT [A] | |
| Maksymalna moc wejściowa [W] | |
| Weight | 35,2 kg |
Three-Phase Hybrid Inverter SolaX Power X3-HYBRID G4 (5.0–15 kW)
The SolaX Power X3-HYBRID G4 hybrid inverter is the fourth generation of this leading three-phase inverter, offering a wide power range from 5.0 to 15 kW. It is designed to provide maximum energy independence for homes and small commercial sites. It combines high efficiency, support for significant PV array oversizing, and ultra-fast switching to UPS-level backup power.
Key features of the SolaX Power X3-HYBRID G4 Hybrid Inverter:
- Reliable backup power: Instant switching to emergency power (EPS) in under 10 ms (UPS level) and support for unbalanced output, ideal for household loads.
- High efficiency and PV flexibility: Allows PV array oversizing up to 150% and a peak efficiency of up to 98.0%, maximizing energy yield.
- Fast battery management: Works with high-voltage lithium-ion batteries (range 180–650 V) with fast charging and discharging at continuous currents up to 30 A.
- Smart features and future readiness: Integrated shade management, VPP readiness (virtual power plants), and parallel operation of up to 10 units, making system expansion easy.
- Durability and easy installation: High IP65 protection rating for outdoor installation and a quick setup time of around 30 minutes (with matbox).
Who is this a good choice for?
The SolaX Power X3-HYBRID G4 is an excellent option for homeowners and small businesses looking for an efficient, reliable core for their PV system with energy storage. With advanced features like ultra-fast UPS-level backup, support for unbalanced loads, and the ability to significantly oversize the PV side, it’s ideal for maximizing self-consumption and ensuring energy security. Its parallel capability and VPP readiness make it an investment prepared for future challenges in the energy market.
| Parameter | X3-Hybrid-5.0-D
X3-Hybrid-5.0-M |
X3-Hybrid-6.0-D
X3-Hybrid-6.0-M |
X3-Hybrid-8.0-D
X3-Hybrid-8.0-M |
X3-Hybrid-10.0-D
X3-Hybrid-10.0-M |
X3-Hybrid-12.0-D
X3-Hybrid-12.0-M |
X3-Hybrid-15.0-D
X3-Hybrid-15.0-M |
|---|---|---|---|---|---|---|
| DC INPUT | ||||||
| Max PV string input power (Wp) | 8000 | 10000 | 12000 | 15000 | 18000 | 18000 |
| Max PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Start-up voltage (V) | 160 | 160 | 160 | 160 | 160 | 160 |
| Nominal input voltage (V) | 630 | 630 | 630 | 630 | 630 | 630 |
| MPP tracker voltage range (V) | 180~950 | 180~950 | 180~950 | 180~950 | 180~950 | 180~950 |
| Number of MPP trackers / strings per MPP tracker | 2(1/1) | 2(1/1) | 2(2/1) | 2(2/1) | 2(2/1) | 2(2/1) |
| Max input current (input A/input B) (A) | 14/14 | 14/14 | 26/14 | 26/14 | 26/14 | 26/14 |
| Max short-circuit current (input A/input B) (A) | 16/16 | 16/16 | 30/16 | 30/16 | 30/16 | 30/16 |
| AC INPUT AND OUTPUT | ||||||
| Rated AC output power (W) | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
| Rated AC output current (A) | 7.2 | 8.7 | 11.6 | 14.5 | 17.5 | 21.8 |
| Max apparent power on AC output (VA) | 5500 | 6600 | 8800 | 11000 | 13200 | 15000 |
| Max AC output current (A) | 8.1 | 9.7 | 12.9 | 16.1 | 19.3 | 24.1 |
| Max apparent power on AC input (VA) | 10000 | 12000 | 16000 | 20000 | 20000 | 20000 |
| Max AC input current (A) | 16.1 | 19.3 | 25.8 | 32.0 | 32.0 | 32.0 |
| Nominal AC voltage (V) | 415/240; 400/230; 380/220 | 415/240; 400/230; 380/220 | 415/240; 400/230; 380/220 | 415/240; 400/230; 380/220 | 415/240; 400/230; 380/220 | 415/240; 400/230; 380/220 |
| Nominal grid frequency / grid frequency range (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Displacement power factor | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging |
| THDi (rated power) (%) | <3 | <3 | <3 | <3 | <3 | |
| BATTERY SPECIFICATIONS | ||||||
| Battery type | Lithium-ion battery | Lithium-ion battery | Lithium-ion battery | Lithium-ion battery | Lithium-ion battery | Lithium-ion battery |
| Battery voltage range (V) | 180~650 | 180~650 | 180~650 | 180~650 | 180~650 | 180~650 |
| Max continuous charge/discharge current (A) | 30 | 30 | 30 | 30 | 30 | 30 |
| EPS OUTPUT WITH BATTERY (OFF-GRID OR BACKUP) | ||||||
| Rated output power (W)*1 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
| Peak apparent power (VA)*1 | 7500, 60s | 9000, 60s | 12000, 60s | 15000, 60s | 15000, 60s | 16500, 60s |
| Max continuous current (A) | 7.2 | 8.7 | 11.6 | 14.5 | 17.5 | 21.8 |
| Nominal voltage (V)/Frequency (Hz) | 400/230; 380/220; 50/60 | 400/230; 380/220; 50/60 | 400/230; 380/220; 50/60 | 400/230; 380/220; 50/60 | 400/230; 380/220; 50/60 | 400/230; 380/220; 50/60 |
| THDv (Linear Load) (%) | <3 | <3 | <3 | <3 | <3 | <3 |
| Switching time to off-grid mode (ms) | <10 | <10 | <10 | <10 | <10 | <10 |
| Parallel operation | YES, 10 | YES, 10 | YES, 10 | YES, 10 | YES, 10 | YES, 10 |
| SYSTEM DATA | ||||||
| Maximum efficiency (%) | 98.00 | 98.00 | 98.00 | 98.00 | 98.00 | 98.00 |
| European efficiency (%) | 97.70 | 97.70 | 97.70 | 97.70 | 97.70 | 97.70 |
| Battery charge/discharge efficiency (%) | 98.5/97.00 | 98.5/97.00 | 98.5/97.00 | 98.5/97.00 | 98.5/97.00 | 98.5/97.00 |
| Standby power consumption @Night (W) | < 40W for hot standby, < 5W for cold standby | < 40W for hot standby, < 5W for cold standby | < 40W for hot standby, < 5W for cold standby | < 40W for hot standby, < 5W for cold standby | < 40W for hot standby, < 5W for cold standby | < 40W for hot standby, < 5W for cold standby |
| Protection rating | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
| Operating temperature range (°C) | -35~60 (derating above +45°C, charging derated above +35°C) | -35~60 (derating above +45°C, charging derated above +35°C) | -35~60 (derating above +45°C, charging derated above +35°C) | -35~60 (derating above +45°C, charging derated above +35°C) | -35~60 (derating above +45°C, charging derated above +35°C) | -35~60 (derating above +45°C, charging derated above +35°C) |
| Max operating altitude (m) | <3000 | <3000 | <3000 | <3000 | <3000 | <3000 |
| Humidity (%) | 0~100 (condensation) | 0~100 (condensation) | 0~100 (condensation) | 0~100 (condensation) | 0~100 (condensation) | 0~100 (condensation) |
| Typical noise emission (dB) | <35 | <35 | <35 | <35 | <45 | <45 |
| Storage temperature (°C) | -40~65 | -40~65 | -40~65 | -40~65 | -40~65 | -40~65 |
| Dimensions (W x H x D) (mm) | 503*503*199 | 503*503*199 | 503*503*199 | 503*503*199 | 503*503*199 | 503*503*199 |
| Weight (kg) | 30 | 30 | 30 | 30 | 30 | 30 |
| Cooling concept | Natural cooling | Natural cooling | Smart cooling | Smart cooling | Smart cooling | Smart cooling |
| Communication interfaces | Meter/WIFI (optional)/DRM/USB/ISO Alarm/RTU485/NTC/BMS/LCD/RS485 | Meter/WIFI (optional)/DRM/USB/ISO Alarm/RTU485/NTC/BMS/LCD/RS485 | Meter/WIFI (optional)/DRM/USB/ISO Alarm/RTU485/NTC/BMS/LCD/RS485 | Meter/WIFI (optional)/DRM/USB/ISO Alarm/RTU485/NTC/BMS/LCD/RS485 | Meter/WIFI (optional)/DRM/USB/ISO Alarm/RTU485/NTC/BMS/LCD/RS485 | Meter/WIFI (optional)/DRM/USB/ISO Alarm/RTU485/NTC/BMS/LCD/RS485 |
| STANDARDS & CERTIFICATIONS | ||||||
| Safety | EN/IEC62109-1/-2 | EN/IEC62109-1/-2 | EN/IEC62109-1/-2 | EN/IEC62109-1/-2 | EN/IEC62109-1/-2 | EN/IEC62109-1/-2 |
| EMC | EN61000-6-1/2/3/4;EN61000-3-2/3/11/12 | EN61000-6-1/2/3/4;EN61000-3-2/3/11/12 | EN61000-6-1/2/3/4;EN61000-3-2/3/11/12 | EN61000-6-1/2/3/4;EN61000-3-2/3/11/12 | EN61000-6-1/2/3/4;EN61000-3-2/3/11/12 | EN61000-6-1/2/3/4;EN61000-3-2/3/11/12 |
| Certification | VDE4105 /G99 /G98 / AS4777 / EN50549/ CEI 0-21 /IEC61727/VDE 0124 etc. | VDE4105 /G99 /G98 / AS4777 / EN50549/ CEI 0-21 /IEC61727/VDE 0124 etc. | VDE4105 /G99 /G98 / AS4777 / EN50549/ CEI 0-21 /IEC61727/VDE 0124 etc. | VDE4105 /G99 /G98 / AS4777 / EN50549/ CEI 0-21 /IEC61727/VDE 0124 etc. | VDE4105 /G99 /G98 / AS4777 / EN50549/ CEI 0-21 /IEC61727/VDE 0124 etc. | VDE4105 /G99 /G98 / AS4777 / EN50549/ CEI 0-21 /IEC61727/VDE 0124 etc. |
Notes:
*1: Test conditions may affect actual values.
D: Use without matebox.
M: Use without matebox.