Three-phase hybrid inverter SolaX X3-NEO-10K-LV, 10 kW

SKU: F20S121-1 EAN: 2010000034279
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type III

SPD Type I+II

SPD – Free slot

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

Weight 51,32 kg
CN 85044086
Price 2 001,48 €
Incl. VAT

2 001,48 €
Incl. VAT

In stock:

12 pcs
Log in to place an order

2 001,48 €
Incl. VAT

In stock:

12 pcs
Log in to place an order

Datasheet Solax X3-NEO-5K-LV - X3-NEO-15K-LV Solax-X3-NEO-5K-LV-X3-NEO-15K-LV-Datasheet.pdf Manual Solax X3-NEO-5K-LV - X3-NEO-15K-LV Solax-X3-NEO-5K-LV-X3-NEO-15K-LV-Manual.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

Warranty

Net width

Net depth

Net height

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type III

SPD Type I+II

SPD – Free slot

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

European efficiency

Weight 51,32 kg
CN 85044086

Three-phase hybrid inverter SolaX X3-NEO-10K-LV, 10 kW

Designed for a solar PV array and a low-voltage battery.

Model specifications

Rated on-grid AC output
10 kW
Maximum recommended PV array power
20 kWp
Number of PV strings
MPPT 1 – 2, MPPT 2 – 1
Maximum input current
MPPT 1 – 36 A, MPPT 2 – 18 A
MPPT voltage range
160–950 V
Battery voltage range
40–60 V
Emergency power supply (EPS) switchover time
< 3 ms
Ingress protection
IP65

Datasheet Solax X3-NEO-5K-LV - X3-NEO-15K-LV Solax-X3-NEO-5K-LV-X3-NEO-15K-LV-Datasheet.pdf Manual Solax X3-NEO-5K-LV - X3-NEO-15K-LV Solax-X3-NEO-5K-LV-X3-NEO-15K-LV-Manual.pdf

Parameter X3-NEO-5K-LV X3-NEO-8K-LV X3-NEO-10K-LV X3-NEO-12K-LV X3-NEO-15K-LV
PV INPUT
Max. recommended PV array power (kWp) 10 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000
Rated PV input voltage (V) 640 640 640 640 640
Operating voltage range (V) 160-950 160-950 160-950 160-950 160-950
MPPT voltage range (V) 160-950 160-950 160-950 160-950 160-950
Start voltage (V) 150 150 150 150 150
Number of MPP trackers / strings per MPP tracker 2/(1/1) 2/(1/1) 2/(2/1) 2/(2/1) 2/(2/2)
Max. input current per MPPT (MPPT1/2) (A) 18/18 18/18 36/18 36/18 36/36
Max. short-circuit input current per MPPT (MPPT1/2) (A) 25/25 25/25 50/25 50/25 50/50
AC INPUT AND OUTPUT (GRID)
Rated output power (kW) 5 8 10 12 15
Rated output current (A) 7.3 11.6 14.5 15.3 17.4
Max. output apparent power (kVA) 5.5 8.8 11 13.2 16.5
Max. continuous output current (A) 8.4 13.4 16.8 20.0 25.0
Rated AC voltage (V) 3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
Max. AC input apparent power (kVA) 10 16 20 24 30
Max. AC input current (A) 15.2 24.3 30.4 36.4 45.5
Rated AC frequency (Hz) 50/60 50/60 50/60 50/60 50/60
AC frequency range (Hz) 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (rated power) (%) <3 <3 <3 <3 <3
BATTERY
Battery type Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery
Battery voltage range (V) 40-60 40-60 40-60 40-60 40-60
Max. charging / discharging current (A) 125 200 250 280 300
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output power (kVA) 5 8 10 12 15
Peak EPS output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Transfer time (ms) <1 <1 <1 <1 <1
EFFICIENCY
Max. efficiency (%) 97.6 97.6 97.6 97.6 97.6
European efficiency (%) 97.0 97.0 97.0 97.0 97.0
ENVIRONMENTAL LIMITS
Protection rating IP65 IP65 IP65 IP65 IP65
Operating ambient temperature range (°C) -25 to 60 -25 to 60 -25 to 60 -25 to 60 -25 to 60
Max. operating altitude (m) 3000 3000 3000 3000 3000
Relative humidity (% RH) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing)
Surge category Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II
GENERAL
Dimensions (W × H × D) (mm) 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258
Net weight (kg) 44.6 44.6 44.6 44.6 44.6
Cooling concept Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN
Power consumption (night) (W) <15 <15 <15 <15 <15
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS
PROTECTION
Protections Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II

(1) Maximum DC input voltage is the upper limit. Higher DC input voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger the inverter protections.
(3) AC frequency range may vary according to national requirements.
(4) Power reduction above +45°C.

Official distribution