Three-phase hybrid inverter SolaX X3-NEO-10K-LV, 10 kW
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 51,32 kg |
| CN | 85044086 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] | |
| European efficiency | |
| Weight | 51,32 kg |
| CN | 85044086 |
Three-phase hybrid inverter SolaX X3-NEO-10K-LV, 10 kW
Designed for a solar PV array and a low-voltage battery.
Model specifications
- Rated on-grid AC output
- 10 kW
- Maximum recommended PV array power
- 20 kWp
- Number of PV strings
- MPPT 1 – 2, MPPT 2 – 1
- Maximum input current
- MPPT 1 – 36 A, MPPT 2 – 18 A
- MPPT voltage range
- 160–950 V
- Battery voltage range
- 40–60 V
- Emergency power supply (EPS) switchover time
- < 3 ms
- Ingress protection
- IP65
| Parameter | X3-NEO-5K-LV | X3-NEO-8K-LV | X3-NEO-10K-LV | X3-NEO-12K-LV | X3-NEO-15K-LV |
|---|---|---|---|---|---|
| PV INPUT | |||||
| Max. recommended PV array power (kWp) | 10 | 16 | 20 | 24 | 30 |
| Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 |
| Rated PV input voltage (V) | 640 | 640 | 640 | 640 | 640 |
| Operating voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
| MPPT voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
| Start voltage (V) | 150 | 150 | 150 | 150 | 150 |
| Number of MPP trackers / strings per MPP tracker | 2/(1/1) | 2/(1/1) | 2/(2/1) | 2/(2/1) | 2/(2/2) |
| Max. input current per MPPT (MPPT1/2) (A) | 18/18 | 18/18 | 36/18 | 36/18 | 36/36 |
| Max. short-circuit input current per MPPT (MPPT1/2) (A) | 25/25 | 25/25 | 50/25 | 50/25 | 50/50 |
| AC INPUT AND OUTPUT (GRID) | |||||
| Rated output power (kW) | 5 | 8 | 10 | 12 | 15 |
| Rated output current (A) | 7.3 | 11.6 | 14.5 | 15.3 | 17.4 |
| Max. output apparent power (kVA) | 5.5 | 8.8 | 11 | 13.2 | 16.5 |
| Max. continuous output current (A) | 8.4 | 13.4 | 16.8 | 20.0 | 25.0 |
| Rated AC voltage (V) | 3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
| Max. AC input apparent power (kVA) | 10 | 16 | 20 | 24 | 30 |
| Max. AC input current (A) | 15.2 | 24.3 | 30.4 | 36.4 | 45.5 |
| Rated AC frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| AC frequency range (Hz) | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 |
| Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
| THDi (rated power) (%) | <3 | <3 | <3 | <3 | <3 |
| BATTERY | |||||
| Battery type | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery |
| Battery voltage range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
| Max. charging / discharging current (A) | 125 | 200 | 250 | 280 | 300 |
| EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||
| Rated EPS output power (kVA) | 5 | 8 | 10 | 12 | 15 |
| Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
| Transfer time (ms) | <1 | <1 | <1 | <1 | <1 |
| EFFICIENCY | |||||
| Max. efficiency (%) | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
| European efficiency (%) | 97.0 | 97.0 | 97.0 | 97.0 | 97.0 |
| ENVIRONMENTAL LIMITS | |||||
| Protection rating | IP65 | IP65 | IP65 | IP65 | IP65 |
| Operating ambient temperature range (°C) | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 |
| Max. operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 |
| Relative humidity (% RH) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) |
| Surge category | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II |
| GENERAL | |||||
| Dimensions (W × H × D) (mm) | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 |
| Net weight (kg) | 44.6 | 44.6 | 44.6 | 44.6 | 44.6 |
| Cooling concept | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
| Communication interfaces | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN |
| Power consumption (night) (W) | <15 | <15 | <15 | <15 | <15 |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Certifications and approvals | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS |
| PROTECTION | |||||
| Protections | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, backfeed current monitoring, residual current detection, overtemperature protection |
| Active anti-islanding method | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
| Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
(1) Maximum DC input voltage is the upper limit. Higher DC input voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger the inverter protections.
(3) AC frequency range may vary according to national requirements.
(4) Power reduction above +45°C.