Energy storage – SOLAREDGE – SE10.0K + Wide 20 kWh + Backup

SKU: F240Y7 EAN: 2010000041505
Manufacturer

Capacity

Price 10 575,72 
Gross

10 575,72 
Gross

10 575,72 
Gross

Datasheet SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Datasheet.pdf Manual SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Manual.pdf Transportation and Storage SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Transportation-and-Storage.pdf Emergency response guide SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Emergency-response-guide.pdf Compatibility Matrix SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Compatibility-Matrix.pdf

Product details

Manufacturer

Capacity

SolarEdge Home Kit with SE10.0K Inverter, Emergency Power Interface, and Energy Storage

The SolarEdge Home 48V kit is a complete solution for residential PV systems, combining a SolarEdge inverter from the SE5K-RWB48, SE8K-RWB48 or SE10K-RWB48 series, the BI-EU3P emergency power interface, and the SolarEdge Home 48V energy storage. The system enables generation, storage and intelligent energy management, and provides backup power in the event of a grid outage. Thanks to full integration within the SolarEdge ecosystem, users get convenient monitoring of system performance, energy flows, battery status and household energy consumption. This solution is designed to increase self-consumption, improve energy independence, and ensure uninterrupted power for the home’s most important devices.

Key features of the SolarEdge Home kit:

  • Comprehensive energy management: A single integrated system handles PV generation, storage, consumption and operation in backup mode.

  • Home backup power: The BI-EU3P interface automatically switches the system into emergency mode during a grid outage, allowing power for the whole house or selected critical circuits.

  • Higher efficiency through DC-side operation: Storing energy on the DC side reduces conversion losses and allows better use of PV generation.

  • Storing excess energy: The SolarEdge Home 48V battery stores unused solar energy for use when PV production is lower or during power outages.

  • Flexible configuration: The system can be tailored to user needs — in inverter power, storage capacity, and the extent of backup power.

  • Expandable: The SolarEdge Home 48V storage is scalable by connecting multiple modules to increase system capacity.

  • Convenient monitoring: The SolarEdge platform provides real-time views of energy production, consumption, battery state of charge, and grid import/export.

  • Safety and reliability: SolarEdge devices are designed for safe operation, user protection and long-term durability.
  • Easy installation and setup: The system supports quick commissioning and configuration via the SolarEdge app, simplifying installation and ongoing operation.

Who is this a good choice for?

The SolarEdge Home 48V kit is an ideal solution for homeowners who want to increase energy independence, make better use of PV energy, and protect against power outages. It is especially suitable for modern households where savings, safety, convenient energy management and the possibility of future expansion matter. By combining an inverter, energy storage and an emergency power interface within one ecosystem, the user gets a cohesive, efficient and future-proof system that maximizes the potential of the PV installation.

Datasheet SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Datasheet.pdf Manual SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Manual.pdf Transportation and Storage SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Transportation-and-Storage.pdf Emergency response guide SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Emergency-response-guide.pdf Compatibility Matrix SolarEdge StorEdge BAT-05K48 Wide SolarEdge-StorEdge-BAT-05K48-Wide-Compatibility-Matrix.pdf

Technical data SolarEdge SE5K – SE10K
SE5K-RWB48 SE8K-RWB48 SE10K-RWB48
OUTPUT – AC, GRID CONNECTION
Rated output power [VA] 5000 8000 10000
Maximum output power [VA] 5000 8000 10000
AC output voltage – phase to phase / phase to neutral (rated) [Vac] 380/220; 400/230 380/220; 400/230 380/220; 400/230
AC – output voltage range – phase to neutral [Vac] 184 – 264.5 184 – 264.5 184 – 264.5
AC frequency [Hz] 50/60 ± 5 % 50/60 ± 5 % 50/60 ± 5 %
Maximum continuous output current (per phase) [A] 8 13 16
Residual current detector / stepped residual current detector [mA] 300 / 30 300 / 30 300 / 30
Supported networks – three-phase 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) 3 / N / PE (star-connected network grounded at neutral point with neutral conductor)
Grid monitoring, islanding protection, configurable power factor, country-dependent configurable threshold values Yes Yes Yes
OUTPUT – AC, BACKUP POWER
Maximum output power [VA] 4500 7200 9000
AC output voltage – phase to phase / phase to neutral (rated) [Vac] 380/220; 400/230 380/220; 400/230 380/220; 400/230
AC – output voltage range – phase to neutral [Vac] 184 – 264.5 184 – 264.5 184 – 264.5
AC frequency [Hz] 50/60 ± 5 % 50/60 ± 5 % 50/60 ± 5 %
Maximum continuous output current (per phase) [A] 7.2 11.7 14.4
Residual current detector / stepped residual current detector [mA] 300 / 30 300 / 30 300 / 30
Supported networks – three-phase 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) 3 / N / PE (star-connected network grounded at neutral point with neutral conductor)
Transformerless, ungrounded Yes Yes Yes
Grid monitoring, provides safe disconnection from the grid in backup mode, configurable power factor, country-dependent configurable threshold values Yes Yes Yes
Automatic transfer time [s] <10 <10 <10
Max. allowed imbalance between phases [kW] 1.66 2.66 3
PV INPUT PARAMETERS
Maximum DC power (module STC) [W] 10000 13000 15000
Maximum input voltage [V DC] 900 900 900
Nominal input voltage [V DC] 750 750 750
Maximum input current [A DC] 13.3 17.3 20
Reverse polarity protection Yes Yes Yes
Ground fault detection Sensitivity 700 kΩ Sensitivity 700 kΩ Sensitivity 700 kΩ
Maximum inverter efficiency [%] 98 98 98
European (weighted) efficiency [%] 97.3 97.6 97.6
INPUT/OUTPUT – ENERGY STORAGE
Supported battery types¹ SolarEdge Home BAT-05K48 energy storage (1–5 battery modules),

Firmware support coming soon for the following batteries: LG Chem RESU3.3, RESU6.5, RESU10, RESU12, RESU13, BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0

Firmware support coming soon for the following batteries: BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0

SolarEdge Home BAT-05K48 energy storage (1–5 battery modules),

Firmware support coming soon for the following batteries: LG Chem RESU3.3, RESU6.5, RESU10, RESU12, RESU13, BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0

Firmware support coming soon for the following batteries: BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0

SolarEdge Home BAT-05K48 energy storage (1–5 battery modules),

Firmware support coming soon for the following batteries: LG Chem RESU3.3, RESU6.5, RESU10, RESU12, RESU13, BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0

Firmware support coming soon for the following batteries: BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0

Maximum charging/discharging power [W] 5000 5000 5000
Input voltage range [V DC] 40-62 40-62 40-62
Maximum continuous input/output current [A DC] 125 125 125
Maximum storage discharge efficiency to grid [%] 96.1 96.1 96.1
Storage-to-inverter communication CAN CAN CAN
OTHER FEATURES
Supported communication interfaces Built-in: 2 x RS485, Ethernet, SolarEdge Home mesh network with antenna Built-in: 2 x RS485, Ethernet, SolarEdge Home mesh network with antenna Built-in: 2 x RS485, Ethernet, SolarEdge Home mesh network with antenna
COMPLIANCE STANDARDS
Safety IEC62109 IEC62109 IEC62109
Grid connection standards² VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438 VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438 VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438
EMC IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, EN55011 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, EN55011 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, EN55011
RoHS Yes Yes Yes
INSTALLATION PARAMETERS
AC output — cable gland diameter [mm] 15-21 15-21 15-21
Storage — cable gland outer diameter [mm] 2 x 11-16.5 2 x 11-16.5 2 x 11-16.5
DC PV input 2 pairs MC4 2 pairs MC4 2 pairs MC4
Dimensions (H x W x D) [mm] 907 x 317 x 192 907 x 317 x 192 907 x 317 x 192
Weight [kg] 37 37 37
Operating temperature range [°C] From -40 to +60 From -40 to +60 From -40 to +60
Cooling Internal and external fans Internal and external fans Internal and external fans
Noise emission [dBA] < 50 < 50 < 50
Ingress protection IP65 – outdoor and indoor IP65 – outdoor and indoor IP65 – outdoor and indoor
Mounting Included bracket Included bracket Included bracket

Parameter BI-EU3P(1)
GRID CONNECTION
AC input current (A) 3*63
AC voltage phase – neutral (min./nom./max.) (V) 160/230/264
AC frequency (min./nom./max.) (Hz) 45/50/55
Rated current of microgrid coupling device (A) 3*63
Transfer time after grid disconnection (s) < 10(2)
OUTPUT TO DISTRIBUTION BOARD
Maximum AC output current (A) 3*63
AC voltage phase – neutral (min./nom./max.) (V) 160/230/264
AC frequency (min./nom./max.) (Hz) 45/50/55
Overvoltage category III
ADDITIONAL FEATURES
Operation during backup power 3-phase + neutral connection from external grid; earth bonding to neutral conductor / option to configure disconnection in the internal grid
Number of communication inputs 1
Communication RS485 and SolarEdge Home mesh network
Energy meter (for import/export) Integrated(3), accuracy 1.25%
Manual control of microgrid coupling device Yes
COMPLIANCE
Safety IEC/EN 62109-1
EMC IEC 61000-6-2, IEC 61000-6-3, IEC 61000-3-11, IEC 61000-3-12, EN55011
MECHANICAL SPECIFICATION
Supported inverters SolarEdge Hub inverter – three-phase with backup power
AC conductor diameter (grid) (mm²) 6 – 16
Conductor diameter (grid/installation) (mm) 25 – 32
AC conductor diameter (installation) (mm²) 6 – 16
Communication cable cross-section (mm²) 0.2 – 1.5
Communication gland diameter (mm) 5 – 15
Weight (kg) < 5
Noise emission (dBA) < 50
Operating temperature range (°C) From -40 to +50
Relative humidity range (%) 0 – 100
Ingress protection IP65
Dimensions (H x W x D) (mm) 390 x 238 x 147
Environmental category Outdoor
Pollution degree 3
Maximum altitude (m) 2000

(1) Applies to PN BI-NEUNU-3P-01
(2) According to local grid settings
(3) Firmware support coming soon

 

Parameter BAT-05K48
Nominal energy (Wh) 5120
Usable energy (100% depth of discharge) (Wh) 4600 / 4850
Continuous output power (charge/discharge) – single module (W) 2825/4096
Continuous output power (charge/discharge) – multiple modules (W) 5000 / 5000
Maximum round-trip efficiency (%) > 95.4
Warranty (years) 10
Voltage range (V DC) 44.8-56.5
Communication interfaces RS485 between modules, CAN bus to inverter
Number of modules per inverter Up to 5 in parallel, up to 4 in one tower
Battery type Lithium-ion – LFP
Supported inverters Application note – Compatibility of 3-phase inverters and SolarEdge Home storage
COMPLIANCE STANDARDS
Safety (cell-level) IEC 62619, UN38.3, UL 9540A
Safety (module-level) UN38.3, IEC 62619, IEC 63056, IEC 62040-1, VDE-AR-E 2510-50
EMC IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, 61000-3-12
MECHANICAL SPECIFICATION
Dimensions (W x H x D) (mm) 540 x 500 x 240
Weight (kg) 54.7
Mounting Stand and wall bracket
Operating temperature (discharge/charge) (°C) From -10 to +50
Storage temperature (12 months between charge cycles) (°C) From -10 to +45
Maximum altitude (m) 2000
Enclosure protection IP65 / NEMA 3R – indoor and outdoor (protection against water and dust ingress)
Cooling Free convection
Noise emission (at 1 m) (dBA) < 25

Note: Part number “BAT-05K48S0B-0*” is for specification purposes.

Official distribution