Energy storage – SOLAREDGE – SE10.0K + Wide 20 kWh + Backup
Gross
Product details
SolarEdge Home Kit with SE10.0K Inverter, Emergency Power Interface, and Energy Storage
The SolarEdge Home 48V kit is a complete solution for residential PV systems, combining a SolarEdge inverter from the SE5K-RWB48, SE8K-RWB48 or SE10K-RWB48 series, the BI-EU3P emergency power interface, and the SolarEdge Home 48V energy storage. The system enables generation, storage and intelligent energy management, and provides backup power in the event of a grid outage. Thanks to full integration within the SolarEdge ecosystem, users get convenient monitoring of system performance, energy flows, battery status and household energy consumption. This solution is designed to increase self-consumption, improve energy independence, and ensure uninterrupted power for the home’s most important devices.
Key features of the SolarEdge Home kit:
-
Comprehensive energy management: A single integrated system handles PV generation, storage, consumption and operation in backup mode.
-
Home backup power: The BI-EU3P interface automatically switches the system into emergency mode during a grid outage, allowing power for the whole house or selected critical circuits.
-
Higher efficiency through DC-side operation: Storing energy on the DC side reduces conversion losses and allows better use of PV generation.
-
Storing excess energy: The SolarEdge Home 48V battery stores unused solar energy for use when PV production is lower or during power outages.
-
Flexible configuration: The system can be tailored to user needs — in inverter power, storage capacity, and the extent of backup power.
-
Expandable: The SolarEdge Home 48V storage is scalable by connecting multiple modules to increase system capacity.
-
Convenient monitoring: The SolarEdge platform provides real-time views of energy production, consumption, battery state of charge, and grid import/export.
- Safety and reliability: SolarEdge devices are designed for safe operation, user protection and long-term durability.
- Easy installation and setup: The system supports quick commissioning and configuration via the SolarEdge app, simplifying installation and ongoing operation.
Who is this a good choice for?
The SolarEdge Home 48V kit is an ideal solution for homeowners who want to increase energy independence, make better use of PV energy, and protect against power outages. It is especially suitable for modern households where savings, safety, convenient energy management and the possibility of future expansion matter. By combining an inverter, energy storage and an emergency power interface within one ecosystem, the user gets a cohesive, efficient and future-proof system that maximizes the potential of the PV installation.
| Technical data SolarEdge SE5K – SE10K | ||||
|---|---|---|---|---|
| SE5K-RWB48 | SE8K-RWB48 | SE10K-RWB48 | ||
| OUTPUT – AC, GRID CONNECTION | ||||
| Rated output power [VA] | 5000 | 8000 | 10000 | |
| Maximum output power [VA] | 5000 | 8000 | 10000 | |
| AC output voltage – phase to phase / phase to neutral (rated) [Vac] | 380/220; 400/230 | 380/220; 400/230 | 380/220; 400/230 | |
| AC – output voltage range – phase to neutral [Vac] | 184 – 264.5 | 184 – 264.5 | 184 – 264.5 | |
| AC frequency [Hz] | 50/60 ± 5 % | 50/60 ± 5 % | 50/60 ± 5 % | |
| Maximum continuous output current (per phase) [A] | 8 | 13 | 16 | |
| Residual current detector / stepped residual current detector [mA] | 300 / 30 | 300 / 30 | 300 / 30 | |
| Supported networks – three-phase | 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) | 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) | 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) | |
| Grid monitoring, islanding protection, configurable power factor, country-dependent configurable threshold values | Yes | Yes | Yes | |
| OUTPUT – AC, BACKUP POWER | ||||
| Maximum output power [VA] | 4500 | 7200 | 9000 | |
| AC output voltage – phase to phase / phase to neutral (rated) [Vac] | 380/220; 400/230 | 380/220; 400/230 | 380/220; 400/230 | |
| AC – output voltage range – phase to neutral [Vac] | 184 – 264.5 | 184 – 264.5 | 184 – 264.5 | |
| AC frequency [Hz] | 50/60 ± 5 % | 50/60 ± 5 % | 50/60 ± 5 % | |
| Maximum continuous output current (per phase) [A] | 7.2 | 11.7 | 14.4 | |
| Residual current detector / stepped residual current detector [mA] | 300 / 30 | 300 / 30 | 300 / 30 | |
| Supported networks – three-phase | 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) | 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) | 3 / N / PE (star-connected network grounded at neutral point with neutral conductor) | |
| Transformerless, ungrounded | Yes | Yes | Yes | |
| Grid monitoring, provides safe disconnection from the grid in backup mode, configurable power factor, country-dependent configurable threshold values | Yes | Yes | Yes | |
| Automatic transfer time [s] | <10 | <10 | <10 | |
| Max. allowed imbalance between phases [kW] | 1.66 | 2.66 | 3 | |
| PV INPUT PARAMETERS | ||||
| Maximum DC power (module STC) [W] | 10000 | 13000 | 15000 | |
| Maximum input voltage [V DC] | 900 | 900 | 900 | |
| Nominal input voltage [V DC] | 750 | 750 | 750 | |
| Maximum input current [A DC] | 13.3 | 17.3 | 20 | |
| Reverse polarity protection | Yes | Yes | Yes | |
| Ground fault detection | Sensitivity 700 kΩ | Sensitivity 700 kΩ | Sensitivity 700 kΩ | |
| Maximum inverter efficiency [%] | 98 | 98 | 98 | |
| European (weighted) efficiency [%] | 97.3 | 97.6 | 97.6 | |
| INPUT/OUTPUT – ENERGY STORAGE | ||||
| Supported battery types¹ | SolarEdge Home BAT-05K48 energy storage (1–5 battery modules),
Firmware support coming soon for the following batteries: LG Chem RESU3.3, RESU6.5, RESU10, RESU12, RESU13, BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0 Firmware support coming soon for the following batteries: BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0 |
SolarEdge Home BAT-05K48 energy storage (1–5 battery modules),
Firmware support coming soon for the following batteries: LG Chem RESU3.3, RESU6.5, RESU10, RESU12, RESU13, BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0 Firmware support coming soon for the following batteries: BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0 |
SolarEdge Home BAT-05K48 energy storage (1–5 battery modules),
Firmware support coming soon for the following batteries: LG Chem RESU3.3, RESU6.5, RESU10, RESU12, RESU13, BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0 Firmware support coming soon for the following batteries: BYD Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0 |
|
| Maximum charging/discharging power [W] | 5000 | 5000 | 5000 | |
| Input voltage range [V DC] | 40-62 | 40-62 | 40-62 | |
| Maximum continuous input/output current [A DC] | 125 | 125 | 125 | |
| Maximum storage discharge efficiency to grid [%] | 96.1 | 96.1 | 96.1 | |
| Storage-to-inverter communication | CAN | CAN | CAN | |
| OTHER FEATURES | ||||
| Supported communication interfaces | Built-in: 2 x RS485, Ethernet, SolarEdge Home mesh network with antenna | Built-in: 2 x RS485, Ethernet, SolarEdge Home mesh network with antenna | Built-in: 2 x RS485, Ethernet, SolarEdge Home mesh network with antenna | |
| COMPLIANCE STANDARDS | ||||
| Safety | IEC62109 | IEC62109 | IEC62109 | |
| Grid connection standards² | VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438 | VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438 | VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438 | |
| EMC | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, EN55011 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, EN55011 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, EN55011 | |
| RoHS | Yes | Yes | Yes | |
| INSTALLATION PARAMETERS | ||||
| AC output — cable gland diameter [mm] | 15-21 | 15-21 | 15-21 | |
| Storage — cable gland outer diameter [mm] | 2 x 11-16.5 | 2 x 11-16.5 | 2 x 11-16.5 | |
| DC PV input | 2 pairs MC4 | 2 pairs MC4 | 2 pairs MC4 | |
| Dimensions (H x W x D) [mm] | 907 x 317 x 192 | 907 x 317 x 192 | 907 x 317 x 192 | |
| Weight [kg] | 37 | 37 | 37 | |
| Operating temperature range [°C] | From -40 to +60 | From -40 to +60 | From -40 to +60 | |
| Cooling | Internal and external fans | Internal and external fans | Internal and external fans | |
| Noise emission [dBA] | < 50 | < 50 | < 50 | |
| Ingress protection | IP65 – outdoor and indoor | IP65 – outdoor and indoor | IP65 – outdoor and indoor | |
| Mounting | Included bracket | Included bracket | Included bracket | |
| Parameter | BI-EU3P(1) |
|---|---|
| GRID CONNECTION | |
| AC input current (A) | 3*63 |
| AC voltage phase – neutral (min./nom./max.) (V) | 160/230/264 |
| AC frequency (min./nom./max.) (Hz) | 45/50/55 |
| Rated current of microgrid coupling device (A) | 3*63 |
| Transfer time after grid disconnection (s) | < 10(2) |
| OUTPUT TO DISTRIBUTION BOARD | |
| Maximum AC output current (A) | 3*63 |
| AC voltage phase – neutral (min./nom./max.) (V) | 160/230/264 |
| AC frequency (min./nom./max.) (Hz) | 45/50/55 |
| Overvoltage category | III |
| ADDITIONAL FEATURES | |
| Operation during backup power | 3-phase + neutral connection from external grid; earth bonding to neutral conductor / option to configure disconnection in the internal grid |
| Number of communication inputs | 1 |
| Communication | RS485 and SolarEdge Home mesh network |
| Energy meter (for import/export) | Integrated(3), accuracy 1.25% |
| Manual control of microgrid coupling device | Yes |
| COMPLIANCE | |
| Safety | IEC/EN 62109-1 |
| EMC | IEC 61000-6-2, IEC 61000-6-3, IEC 61000-3-11, IEC 61000-3-12, EN55011 |
| MECHANICAL SPECIFICATION | |
| Supported inverters | SolarEdge Hub inverter – three-phase with backup power |
| AC conductor diameter (grid) (mm²) | 6 – 16 |
| Conductor diameter (grid/installation) (mm) | 25 – 32 |
| AC conductor diameter (installation) (mm²) | 6 – 16 |
| Communication cable cross-section (mm²) | 0.2 – 1.5 |
| Communication gland diameter (mm) | 5 – 15 |
| Weight (kg) | < 5 |
| Noise emission (dBA) | < 50 |
| Operating temperature range (°C) | From -40 to +50 |
| Relative humidity range (%) | 0 – 100 |
| Ingress protection | IP65 |
| Dimensions (H x W x D) (mm) | 390 x 238 x 147 |
| Environmental category | Outdoor |
| Pollution degree | 3 |
| Maximum altitude (m) | 2000 |
(1) Applies to PN BI-NEUNU-3P-01
(2) According to local grid settings
(3) Firmware support coming soon
| Parameter | BAT-05K48 |
|---|---|
| Nominal energy (Wh) | 5120 |
| Usable energy (100% depth of discharge) (Wh) | 4600 / 4850 |
| Continuous output power (charge/discharge) – single module (W) | 2825/4096 |
| Continuous output power (charge/discharge) – multiple modules (W) | 5000 / 5000 |
| Maximum round-trip efficiency (%) | > 95.4 |
| Warranty (years) | 10 |
| Voltage range (V DC) | 44.8-56.5 |
| Communication interfaces | RS485 between modules, CAN bus to inverter |
| Number of modules per inverter | Up to 5 in parallel, up to 4 in one tower |
| Battery type | Lithium-ion – LFP |
| Supported inverters | Application note – Compatibility of 3-phase inverters and SolarEdge Home storage |
| COMPLIANCE STANDARDS | |
| Safety (cell-level) | IEC 62619, UN38.3, UL 9540A |
| Safety (module-level) | UN38.3, IEC 62619, IEC 63056, IEC 62040-1, VDE-AR-E 2510-50 |
| EMC | IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, 61000-3-12 |
| MECHANICAL SPECIFICATION | |
| Dimensions (W x H x D) (mm) | 540 x 500 x 240 |
| Weight (kg) | 54.7 |
| Mounting | Stand and wall bracket |
| Operating temperature (discharge/charge) (°C) | From -10 to +50 |
| Storage temperature (12 months between charge cycles) (°C) | From -10 to +45 |
| Maximum altitude (m) | 2000 |
| Enclosure protection | IP65 / NEMA 3R – indoor and outdoor (protection against water and dust ingress) |
| Cooling | Free convection |
| Noise emission (at 1 m) (dBA) | < 25 |
Note: Part number “BAT-05K48S0B-0*” is for specification purposes.