Battery module – GOODWE – ESA GW6.0-BAT-D-G20 – 0,5C – 6 kWh – HV
| Manufacturer | |
|---|---|
| Battery cell type | |
| Required number of modules | |
| Depth of Discharge | |
| CAN | |
| RS485 | |
| Warranty | |
| Net width | |
| Net depth | |
| Weight | 67,58 kg |
| CN | 85076000 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Battery cell type | |
| Required number of modules | |
| Depth of Discharge | |
| CAN | |
| RS485 | |
| Warranty | |
| Net width | |
| Net depth | |
| Weight | 67,58 kg |
| CN | 85076000 |
Lynx D G2 Series
The high-voltage energy storage units of the Lynx D G2 series are an advanced and versatile solution with module capacities from 5 to 9 kWh, designed for self-consumption, price arbitrage and off-grid systems. These devices feature safe lithium iron phosphate (LiFePO4) technology, a long lifespan of up to 10 000 cycles and an integrated heating and cooling system. Thanks to a flexible modular design they allow system expansion up to 12 units and free mixing of modules with different capacities.
Key features of the Lynx D G2 Series:
- High performance and longevity: Durability up to 10 000 cycles and charge/discharge rate of 0,5C for 6 and 9 kWh modules and 1C for 5 and 8 kWh modules.
- Advanced safety: IP66 protection class, thermal-electric isolation and an integrated aerosol-based fire suppression system providing active extinguishing.
- Flexible scalability: Ability to connect up to 12 battery modules in the system, multi-cluster expansion and the option to mix modules of different capacities.
- Operation in harsh conditions: Integrated heating and cooling system ensures reliable operation across a wide temperature range from -20°C to 55°C.
- Intelligent management: Each individual module is equipped with an integrated Battery Management System (BMS) and a DC/DC converter, enabling remote updates and diagnostics.
Who is this a good choice for?
The Lynx D G2 Series is an ideal choice for single-family homeowners and investors seeking a flexible, safe and efficient energy storage solution to work with single- and three-phase systems and GoodWe hybrid inverters. With the possibility of expansion at any time and resistance to harsh external conditions, this solution works very well in modern installations focused on maximum self-consumption and energy independence.
| Parameter | GW5.1-BAT-D-G20 | GW8.3-BAT-D-G20 | GW6.0-BAT-D-G20 | GW9.0-BAT-D-G20 |
|---|---|---|---|---|
| Battery type | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) |
| Rated energy (kWh) | 5,12 | 8,32 | 6,0 | 9,0 |
| Usable energy (kWh) | 5,0 | 8,0 | 5,8 | 8,7 |
| Operating voltage range (single-phase system) (V) | 350 – 550 | 350 – 550 | 350 – 550 | 350 – 550 |
| Operating voltage range (three-phase system) (V) | 700 – 950 | 700 – 950 | 700 – 950 | 700 – 950 |
| Max. input current (system) (A) | 12,0 | 19,0 | 7,1 | 10,7 |
| Max. output current (system) (A) | 13,2 | 21,0 | 7,9 | 11,8 |
| Max. input power (system) (kW) | 5,0 | 8,0 | 3,0 | 4,5 |
| Max. output power (system) (kW) | 5,0 | 8,0 | 3,0 | 4,5 |
| Peak output power (system) (kW) | 7,5 @ 10 s | 12,0 @ 10 s | 4,5 @ 10 s | 6,75 @ 10 s |
| Charge temperature range (°C) | -18 ~ +55 | -18 ~ +55 | -20 ~ +55 | -20 ~ +55 |
| Discharge temperature range (°C) | -20 ~ +55 | -20 ~ +55 | -20 ~ +55 | -20 ~ +55 |
| Relative humidity (%) | 4 – 100% | 4 – 100% | 4 – 100% | 4 – 100% |
| Max. operating altitude (m) | 4000 | 4000 | 4000 | 4000 |
| Noise emission (dB) | ≤29 | ≤29 | ≤27 | ≤27 |
| Communication | CAN | CAN | CAN & RS485 | CAN & RS485 |
| Weight (kg) | 57,5 ± 1 | 79 ± 1 | 61 ± 1 | 77 ± 1 |
| IP rating | IP66 | IP66 | IP66 | IP66 |
| Dimensions (W × H × D) (mm) | 800 × 326 × 270 | 800 × 326 × 270 | 800 × 326 × 270 | 800 × 326 × 270 |
| Function configuration | Heating (integrated); Aerosol extinguishing (integrated) | Heating (integrated); Aerosol extinguishing (integrated) | Heating (integrated); Aerosol extinguishing (integrated) | Heating (integrated); Aerosol extinguishing (integrated) |
| Max. storage time | 12 months (-20°C ~ +35°C) / 6 months (+35°C ~ +45°C) | 12 months (-20°C ~ +35°C) / 6 months (+35°C ~ +45°C) | 12 months (-20°C ~ +35°C) / 6 months (+35°C ~ +45°C) | 12 months (-20°C ~ +35°C) / 6 months (+35°C ~ +45°C) |
| Scalability | Up to 12 modules | Up to 12 modules | Up to 12 modules | Up to 12 modules |
| Mounting method | Floor stacked on the floor / wall-mounted | Floor stacked on the floor / wall-mounted | Floor stacked on the floor / grounded | Floor stacked on the floor / grounded |
| Cycle life | ≥8000 cycles | ≥8000 cycles | ≥10000 cycles | ≥10000 cycles |
| Standards and certifications | ||||
| Safety | IEC62619, IEC60730, EN62477, IEC63056, IEC62040, CE, CEC, VDE2510 | IEC62619, IEC60730, EN62477, IEC63056, IEC62040, CE, CEC, VDE2510 | IEC62619, IEC60730, EN62477, IEC63056, IEC62040, CE, CEC, Regulation 2023/1542, VDE2510-50 | IEC62619, IEC60730, EN62477, IEC63056, IEC62040, CE, CEC, Regulation 2023/1542, VDE2510-50 |
| EMC | CE, RCM | CE, RCM | CE, RCM | CE, RCM |
| Transport | UN38.3, ADR | UN38.3, ADR | UN38.3, ADR | UN38.3, ADR |
* Power derating occurs depending on temperature and state of charge (SOC). Actual available usable energy may vary depending on operating conditions.