Optimizer – SOLAREDGE – S440 – 1DM4MRM – NA24 – long cable
| Manufacturer | |
|---|---|
| Application | |
| Rated input power | |
| Maximum short-circuit current | |
| Maximum output current [A] | |
| Maximum efficiency | |
| Cable length | |
| Mounting method | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| Quantity per package | |
| Quantity per pallet | |
| Weight | 0,706 kg |
| CN | 90308900 |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Application | |
| Rated input power | |
| Maximum short-circuit current | |
| Maximum output current [A] | |
| Maximum efficiency | |
| Cable length | |
| Mounting method | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| Quantity per package | |
| Quantity per pallet | |
| Weight | 0,706 kg |
| CN | 90308900 |
SolarEdge S440, S500
The SolarEdge S440 and S500 power optimizers are specifically designed to work with SolarEdge inverters intended for residential buildings, ensuring optimal energy production from each photovoltaic module. This series guarantees the highest efficiency and design flexibility, maximizing the use of available roof area. Thanks to advanced safety features and robust construction, they are a reliable choice for modern photovoltaic systems.
Key features of SolarEdge S440, S500:
- Highest efficiency: Peak efficiency up to 99,5% (weighted efficiency 98,6%) reduces losses caused by module non-uniformity and partial shading.
- Rated DC input power: Depending on the model, 440 W for the S440 and 500 W for the S500.
- Enhanced safety: The SafeDC feature reduces module-level voltage in accordance with VDE-AR-E 2100-712 requirements, ensuring the safety of installers, service personnel and emergency responders.
- Connector anomaly detection: The system detects abnormal photovoltaic connector behavior, preventing potential safety issues.
- Bifacial module compatibility: Flexible system design and full compatibility with bifacial photovoltaic modules.
- Durability and long-term protection: Devices are covered by a 25-year manufacturer’s warranty and have an IP68 / NEMA 6P rating.
Who is this a good choice for?
The S440 and S500 power optimizers are an excellent choice for single-family homeowners and investors planning residential photovoltaic installations, especially in conditions of partial shading or complex roof geometry. This solution is intended for those seeking maximum energy performance, design flexibility, and the highest standards of fire and electrical safety.
| Parameter | S440 | S500 |
|---|---|---|
| DC input data | ||
| Rated DC input power (W) | 440 | 500 |
| Absolute maximum input voltage (Voc) (V DC) | 60 | 60 |
| MPPT operating range (V DC) | 8–60 | 8–60 |
| Maximum short-circuit current (Isc) (A DC) | 14,5 | 14,5 |
| Maximum efficiency (%) | 99,5 | 99,5 |
| Weighted efficiency (%) | 98,6 | 98,6 |
| Surge category | II | II |
| Output (during operation) | ||
| Maximum output current (A DC) | 15 | 15 |
| Maximum output voltage (V DC) | 60 | 60 |
| Output (standby mode) | ||
| Safe optimizer output voltage (V DC) | 1 | 1 |
| Installation specifications | ||
| Maximum allowable system voltage (V DC) | 1000 | 1000 |
| Dimensions (W × L × H) (mm) | 129 × 153 × 30 | 129 × 153 × 30 |
| Weight (with cables) (g) | 655 | 655 |
| Input connector | MC4 | MC4 |
| Input cable length (m) | 0,1 | 0,1 |
| Output connector | MC4 | MC4 |
| Output cable length (m) | (+) 2,3 / (-) 0,10 | (+) 2,3 / (-) 0,10 |
| Operating temperature range (°C) | od -40 do +85 | od -40 do +85 |
| Protection rating | IP68 / NEMA6P | IP68 / NEMA6P |
| Relative humidity (%) | 0–100 | 0–100 |
| Standards compliance | ||
| Electromagnetic compatibility (EMC) | FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 | FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 |
| Safety | IEC62109-1 (safety class II), UL1741 | IEC62109-1 (safety class II), UL1741 |
| Housing materials | UL94 V-0, UV resistant | UL94 V-0, UV resistant |
| RoHS compliance | Yes | Yes |
| Fire safety | VDE-AR-E 2100-712:2013-05 | VDE-AR-E 2100-712:2013-05 |
| Photovoltaic system design | ||
| Minimum string length (single-phase inverter) | 8 | 8 |
| Minimum string length (three-phase inverter) | 16 | 16 |
| Minimum string length (three-phase inverter 277/480 V) | 18 | 18 |
| Maximum string length (single-phase inverter) | 25 | 25 |
| Maximum string length (three-phase inverter) | 50 | 50 |
| Maximum string length (three-phase inverter 277/480 V) | 50 | 50 |
| Maximum nominal power per string – single-phase inverter (W) | 5700 (HD-Wave) / 5250 | 5700 (HD-Wave) / 5250 |
| Maximum nominal power per string – three-phase inverter (W) | 11 250 | 11 250 |
| Maximum nominal power per string – three-phase inverter 277/480 V (W) | 12 750 | 12 750 |
| Parallel strings of different lengths or orientations | Yes | Yes |
* For ambient temperatures above +70°C power is reduced. Optimizers are compatible with bifacial modules.
| Parameter | S440 | S500 |
|---|---|---|
| DC input data | ||
| Rated DC input power (W) | 440 | 500 |
| Absolute maximum input voltage (Voc) (V DC) | 60 | 60 |
| MPPT operating range (V DC) | 8–60 | 8–60 |
| Maximum short-circuit current (Isc) (A DC) | 14,5 | 14,5 |
| Maximum efficiency (%) | 99,5 | 99,5 |
| Weighted efficiency (%) | 98,6 | 98,6 |
| Surge category | II | II |
| Output (during operation) | ||
| Maximum output current (A DC) | 15 | 15 |
| Maximum output voltage (V DC) | 60 | 60 |
| Output (standby mode) | ||
| Safe optimizer output voltage (V DC) | 1 | 1 |
| Installation specifications | ||
| Maximum allowable system voltage (V DC) | 1000 | 1000 |
| Dimensions (W × L × H) (mm) | 129 × 153 × 30 | 129 × 153 × 30 |
| Weight (with cables) (g) | 655 | 655 |
| Input connector | MC4 | MC4 |
| Input cable length (m) | 0,1 | 0,1 |
| Output connector | MC4 | MC4 |
| Output cable length (m) | (+) 2,3 / (-) 0,10 | (+) 2,3 / (-) 0,10 |
| Operating temperature range (°C) | od -40 do +85 | od -40 do +85 |
| Protection rating | IP68 / NEMA6P | IP68 / NEMA6P |
| Relative humidity (%) | 0–100 | 0–100 |
| Standards compliance | ||
| Electromagnetic compatibility (EMC) | FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 | FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 |
| Safety | IEC62109-1 (safety class II), UL1741 | IEC62109-1 (safety class II), UL1741 |
| Housing materials | UL94 V-0, UV resistant | UL94 V-0, UV resistant |
| RoHS compliance | Yes | Yes |
| Fire safety | VDE-AR-E 2100-712:2013-05 | VDE-AR-E 2100-712:2013-05 |
| Photovoltaic system design | ||
| Minimum string length (single-phase inverter) | 8 | 8 |
| Minimum string length (three-phase inverter) | 16 | 16 |
| Minimum string length (three-phase inverter 277/480 V) | 18 | 18 |
| Maximum string length (single-phase inverter) | 25 | 25 |
| Maximum string length (three-phase inverter) | 50 | 50 |
| Maximum string length (three-phase inverter 277/480 V) | 50 | 50 |
| Maximum nominal power per string – single-phase inverter (W) | 5700 (HD-Wave) / 5250 | 5700 (HD-Wave) / 5250 |
| Maximum nominal power per string – three-phase inverter (W) | 11 250 | 11 250 |
| Maximum nominal power per string – three-phase inverter 277/480 V (W) | 12 750 | 12 750 |
| Parallel strings of different lengths or orientations | Yes | Yes |
* For ambient temperatures above +70°C power is reduced. Optimizers are compatible with bifacial modules.