Heat pump – GRUNDIG – GHP-MM08 – monoblock – single-phase

SKU: F1C08 EAN: 2010000046074
Manufacturer

Net width

Net depth

Net height

Price 1 321,67 €
Incl. VAT

1 321,67 €
Incl. VAT

In stock:

8 pcs
Log in to place an order

1 321,67 €
Incl. VAT

In stock:

8 pcs
Log in to place an order

Product details

Manufacturer

Net width

Net depth

Net height

Grundig Monoblock Series GHP-MM Heat Pumps

The Grundig heat pump is an environmentally friendly all-in-one system that provides reliable heating, cooling and domestic hot water production without the use of fossil fuels. Using advanced inverter technology and the eco-friendly refrigerant R32, these units ensure high energy efficiency and stable operation even in challenging climatic conditions. The series includes models with heating capacities from 8,1 to 15,8 kW, tailored to the diverse needs of modern construction.

Key features of the Grundig Monoblock Series GHP-MM Heat Pump:

  • Eco-friendly refrigerant R32: Has a low global warming potential and zero impact on the ozone layer, translating into lower CO2 emissions.
  • High performance at low temperatures: Stable heating operation at outdoor temperatures down to -25°C and water outlet temperatures up to 65°C without electric heater assistance.
  • Renowned components: Equipped with a Mitsubishi DC Inverter compressor, Panasonic DC Inverter fan drive, SANHUA 4-way valve and expansion valve, Alfa Laval plate heat exchanger and WILO pump.
  • High energy class: Energy efficiency class A+++ for 35°C water outlet temperature and A++ for 55°C.
  • Advanced control: Modern wired control panel with touch buttons and Wi-Fi support, which can function as a room thermostat with real-time parameter monitoring.
  • Comprehensive 3-in-1 function: The system supports heating, cooling and domestic hot water production with the possibility of cascading up to 8 units.

Who is this a good choice for?

Grundig Monoblock series heat pumps are an ideal solution for owners of single-family homes and residential buildings seeking independent, energy-efficient and environmentally friendly heating systems. With a wide power range from 8 to nearly 16 kW and stable operation at low temperatures, the unit performs well in both new builds and renovated homes, providing high thermal comfort and lower operating costs.

Parameter GHP-MM08 GHP-MM10 GHP-MM12 GHP-MM312 GHP-MM314 GHP-MM316
General data and functionalities
Electrical protection class Class I Class I Class I Class I Class I Class I
Power supply (V / ph / Hz) 220–240 V / 1 phase / 50 Hz 220–240 V / 1 phase / 50 Hz 220–240 V / 1 phase / 50 Hz 380–415 V / 3 phase / 50 Hz 380–415 V / 3 phase / 50 Hz 380–415 V / 3 phase / 50 Hz
Refrigerant type R32 R32 R32 R32 R32 R32
Refrigerant charge (g) 1300 1500 1750 1750 2100 2100
Control type LCD / Wi-Fi LCD / Wi-Fi LCD / Wi-Fi LCD / Wi-Fi LCD / Wi-Fi LCD / Wi-Fi
Automatic restart Yes Yes Yes Yes Yes Yes
Timer 0,5–24 h 0,5–24 h 0,5–24 h 0,5–24 h 0,5–24 h 0,5–24 h
Defrost Yes Yes Yes Yes Yes Yes
Hot start Yes Yes Yes Yes Yes Yes
Energy saving mode (ECO) Yes Yes Yes Yes Yes Yes
Holiday mode Yes Yes Yes Yes Yes Yes
ZDS control system Option Option Option Option Option Option
Hybrid system operation Yes Yes Yes Yes Yes Yes
Cascade operation (up to 8 units) Yes Yes Yes Yes Yes Yes
Recommended circuit breaker for unit / heater (A) 20 / 16 20 / 16 25 / 16 25 25 25
Electric heater input power (W) 3000 3000 3000 9000 9000 9000
Water connection diameter (inlet / outlet) 1″ (external thread) 1″ (external thread) 1″ (external thread) 1″ (external thread) 1″ (external thread) 1″ (external thread)
Y-type filter included Yes Yes Yes Yes Yes Yes
Control panel included Yes Yes Yes Yes Yes Yes
Water temperature sensor included Yes Yes Yes Yes Yes Yes
Heating and cooling performance
Heating mode (A7/W35)¹
Heating capacity (kW) 8,1 10,1 12,1 12,1 14,0 15,8
Power input (kW) 1,80 2,09 2,65 2,65 2,98 3,53
COP 4,50 4,83 4,57 4,57 4,70 4,48
Heating mode (A7/W45)²
Heating capacity (kW) 8,5 10,2 12,1 12,1 14,1 16,0
Power input (kW) 2,61 2,79 3,37 3,37 3,95 4,62
COP 3,20 3,65 3,59 3,59 3,57 3,46
Heating mode (A7/W55)³
Heating capacity (kW) 7,7 9,6 12,2 12,2 14,2 16,2
Power input (kW) 2,98 3,22 4,15 4,15 5,07 5,74
COP 2,58 2,98 2,94 2,94 2,80 2,82
Cooling mode (A35/W18)⁴
Cooling capacity (kW) 8,2 10,0 12,0 12,0 13,9 16,2
Power input (kW) 1,75 2,42 2,64 2,64 3,35 3,94
EER 4,65 4,14 4,55 4,55 4,15 4,11
Cooling mode (A35/W7)⁵
Cooling capacity (kW) 7,6 8,8 11,5 11,5 13,7 16,1
Power input (kW) 2,55 2,97 4,05 4,05 5,29 5,96
EER 2,97 2,96 2,84 2,84 2,59 2,70
Seasonal efficiency and acoustics
Energy efficiency class (LWT 35°C) A+++ A+++ A+++ A+++ A+++ A+++
Energy efficiency class (LWT 55°C) A++ A++ A++ A++ A++ A++
Seasonal efficiency SCOP (LWT 35°C) 4,62 4,86 4,77 4,77 4,67 4,87
Seasonal efficiency SCOP (LWT 55°C) 3,32 3,51 3,60 3,60 3,62 3,65
Seasonal efficiency SEER (LWT 7°C) 5,17 4,66 5,45 5,45 5,59 5,38
Seasonal efficiency SEER (LWT 18°C) 8,31 8,23 8,29 8,29 8,33 8,26
Sound power level⁶ (dB(A)) 59 60 64 64 65 68
Operating temperature ranges
Ambient temperature range – cooling (°C) 5–48 5–48 5–48 5–48 5–48 5–48
Ambient temperature range – heating (°C) -25–35 -25–35 -25–35 -25–35 -25–35 -25–35
Ambient temperature range – DHW (°C) -25–43 -25–43 -25–43 -25–43 -25–43 -25–43
Outlet water temperature range – cooling (°C) 7–25 7–25 7–25 7–25 7–25 7–25
Outlet water temperature range – heating (°C) 25–65 25–65 25–65 25–65 25–65 25–65
Outlet water temperature range – DHW (°C) 25–55 25–55 25–55 25–55 25–55 25–55
Dimensions and weight
Net dimensions (W × H × D) (mm) 1125 × 703 × 370 1135 × 803 × 396 1135 × 803 × 396 1135 × 803 × 396 1203 × 860 × 436 1203 × 860 × 436
Net weight (kg) 82,5 99 103 103 123 123
Gross dimensions (W × H × D) (mm) 1200 × 425 × 865 1260 × 982 × 488 1260 × 982 × 488 1260 × 982 × 488 1285 × 1040 × 495 1285 × 1040 × 495
Gross weight (kg) 96 114 126 126 145 145

Measurement conditions: ¹ Heating: outdoor temp. 7°C DB, 85% R.H.; water inlet/outlet temp. 30°C/35°C (according to EN14511). ² Heating: outdoor temp. 7°C DB, 85% R.H.; water inlet/outlet temp. 40°C/45°C (according to EN14511). ³ Heating: outdoor temp. 7°C DB, 85% R.H.; water inlet/outlet temp. 47°C/55°C (according to EN14511). ⁴ Cooling: outdoor temp. 35°C DB, 85% R.H.; water inlet/outlet temp. 23°C/18°C (according to EN14511). ⁵ Cooling: outdoor temp. 35°C DB, 85% R.H.; water inlet/outlet temp. 12°C/7°C (according to EN14511). ⁶ Sound level test in accordance with EN12102-1.

Official distribution