Heat pump – GRUNDIG – GHP-MM12 – monoblock – single-phase
Incl. VAT
Product details
Grundig Monoblock Series Heat Pumps GHP-MM
The Grundig heat pump is an environmentally friendly all-in-one system that provides reliable heating, cooling and domestic hot water production without the use of fossil fuels. Using advanced inverter technology and the eco-friendly refrigerant R32, these units ensure high energy efficiency and stable operation even in harsh climatic conditions. The series includes models with heating capacities from 8.1 to 15.8 kW, tailored to the diverse needs of modern buildings.
Key features of the Grundig Monoblock Series GHP-MM heat pumps:
- Eco-friendly refrigerant R32: Has a low global warming potential and zero ozone depletion potential, resulting in lower CO2 emissions.
- High performance at low temperatures: Stable heating operation at outdoor temperatures down to -25°C and water outlet temperature up to 65°C without electric heater assistance.
- Renowned components: Equipped with a Mitsubishi DC Inverter compressor, Panasonic DC Inverter fan drive, 4-way valve and SANHUA expansion valve, Alfa Laval plate heat exchanger and WILO pump.
- High energy class: Energy efficiency class A+++ for water outlet temperature 35°C and A++ for 55°C.
- Advanced control: Modern wired control panel with touch buttons and Wi‑Fi support, which can function as a room thermostat with real-time parameter monitoring.
- Comprehensive 3-in-1 function: The system supports heating, cooling and domestic hot water preparation with the possibility of cascading up to 8 units.
Who is this a good choice for?
Grundig Monoblock series heat pumps are an ideal solution for owners of single-family homes and residential buildings seeking independent, energy-efficient and eco-friendly heating systems. With a wide power range from 8 to nearly 16 kW and stable operation at low temperatures, the unit is suitable for both newly built and renovated homes, offering high thermal comfort and lower operating costs.
| Parameter | GHP-MM08 | GHP-MM10 | GHP-MM12 | GHP-MM312 | GHP-MM314 | GHP-MM316 |
|---|---|---|---|---|---|---|
| General data and functionalities | ||||||
| Electrical protection class | Class I | Class I | Class I | Class I | Class I | Class I |
| Power supply (V / f / Hz) | 220–240 V / 1 phase / 50 Hz | 220–240 V / 1 phase / 50 Hz | 220–240 V / 1 phase / 50 Hz | 380–415 V / 3 phase / 50 Hz | 380–415 V / 3 phase / 50 Hz | 380–415 V / 3 phase / 50 Hz |
| Type of refrigerant | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant charge (g) | 1300 | 1500 | 1750 | 1750 | 2100 | 2100 |
| Control type | LCD / Wi-Fi | LCD / Wi-Fi | LCD / Wi-Fi | LCD / Wi-Fi | LCD / Wi-Fi | LCD / Wi-Fi |
| Auto restart | Yes | Yes | Yes | Yes | Yes | Yes |
| Timer (Timer) | 0,5–24 h | 0,5–24 h | 0,5–24 h | 0,5–24 h | 0,5–24 h | 0,5–24 h |
| Defrost | Yes | Yes | Yes | Yes | Yes | Yes |
| Hot start | Yes | Yes | Yes | Yes | Yes | Yes |
| Energy saving mode (ECO) | Yes | Yes | Yes | Yes | Yes | Yes |
| Holiday mode | Yes | Yes | Yes | Yes | Yes | Yes |
| ZDS control system | Option | Option | Option | Option | Option | Option |
| Hybrid system operation | Yes | Yes | Yes | Yes | Yes | Yes |
| Cascade operation (up to 8 units) | Yes | Yes | Yes | Yes | Yes | Yes |
| Recommended circuit breaker for unit / heater (A) | 20 / 16 | 20 / 16 | 25 / 16 | 25 | 25 | 25 |
| Electric heater input power (W) | 3000 | 3000 | 3000 | 9000 | 9000 | 9000 |
| Water connection diameter (inlet / outlet) | 1″ (external thread) | 1″ (external thread) | 1″ (external thread) | 1″ (external thread) | 1″ (external thread) | 1″ (external thread) |
| Y-type filter included | Yes | Yes | Yes | Yes | Yes | Yes |
| Control panel included | Yes | Yes | Yes | Yes | Yes | Yes |
| Water temperature sensor included | Yes | Yes | Yes | Yes | Yes | Yes |
| Heating and cooling performance | ||||||
| Heating mode (A7/W35)¹ | ||||||
| Heating capacity (kW) | 8,1 | 10,1 | 12,1 | 12,1 | 14,0 | 15,8 |
| Power input (kW) | 1,80 | 2,09 | 2,65 | 2,65 | 2,98 | 3,53 |
| COP | 4,50 | 4,83 | 4,57 | 4,57 | 4,70 | 4,48 |
| Heating mode (A7/W45)² | ||||||
| Heating capacity (kW) | 8,5 | 10,2 | 12,1 | 12,1 | 14,1 | 16,0 |
| Power input (kW) | 2,61 | 2,79 | 3,37 | 3,37 | 3,95 | 4,62 |
| COP | 3,20 | 3,65 | 3,59 | 3,59 | 3,57 | 3,46 |
| Heating mode (A7/W55)³ | ||||||
| Heating capacity (kW) | 7,7 | 9,6 | 12,2 | 12,2 | 14,2 | 16,2 |
| Power input (kW) | 2,98 | 3,22 | 4,15 | 4,15 | 5,07 | 5,74 |
| COP | 2,58 | 2,98 | 2,94 | 2,94 | 2,80 | 2,82 |
| Cooling mode (A35/W18)⁴ | ||||||
| Cooling capacity (kW) | 8,2 | 10,0 | 12,0 | 12,0 | 13,9 | 16,2 |
| Power input (kW) | 1,75 | 2,42 | 2,64 | 2,64 | 3,35 | 3,94 |
| EER | 4,65 | 4,14 | 4,55 | 4,55 | 4,15 | 4,11 |
| Cooling mode (A35/W7)⁵ | ||||||
| Cooling capacity (kW) | 7,6 | 8,8 | 11,5 | 11,5 | 13,7 | 16,1 |
| Power input (kW) | 2,55 | 2,97 | 4,05 | 4,05 | 5,29 | 5,96 |
| EER | 2,97 | 2,96 | 2,84 | 2,84 | 2,59 | 2,70 |
| Seasonal efficiency and acoustics | ||||||
| Energy efficiency class (LWT 35°C) | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
| Energy efficiency class (LWT 55°C) | A++ | A++ | A++ | A++ | A++ | A++ |
| Seasonal efficiency SCOP (LWT 35°C) | 4,62 | 4,86 | 4,77 | 4,77 | 4,67 | 4,87 |
| Seasonal efficiency SCOP (LWT 55°C) | 3,32 | 3,51 | 3,60 | 3,60 | 3,62 | 3,65 |
| Seasonal efficiency SEER (LWT 7°C) | 5,17 | 4,66 | 5,45 | 5,45 | 5,59 | 5,38 |
| Seasonal efficiency SEER (LWT 18°C) | 8,31 | 8,23 | 8,29 | 8,29 | 8,33 | 8,26 |
| Sound power level⁶ (dB(A)) | 59 | 60 | 64 | 64 | 65 | 68 |
| Operating temperature ranges | ||||||
| Ambient temperature range – cooling (°C) | 5–48 | 5–48 | 5–48 | 5–48 | 5–48 | 5–48 |
| Ambient temperature range – heating (°C) | -25–35 | -25–35 | -25–35 | -25–35 | -25–35 | -25–35 |
| Ambient temperature range – DHW (°C) | -25–43 | -25–43 | -25–43 | -25–43 | -25–43 | -25–43 |
| Water outlet temperature range – cooling (°C) | 7–25 | 7–25 | 7–25 | 7–25 | 7–25 | 7–25 |
| Water outlet temperature range – heating (°C) | 25–65 | 25–65 | 25–65 | 25–65 | 25–65 | 25–65 |
| Water outlet temperature range – DHW (°C) | 25–55 | 25–55 | 25–55 | 25–55 | 25–55 | 25–55 |
| Dimensions and weight | ||||||
| Net dimensions (W × H × D) (mm) | 1125 × 703 × 370 | 1135 × 803 × 396 | 1135 × 803 × 396 | 1135 × 803 × 396 | 1203 × 860 × 436 | 1203 × 860 × 436 |
| Net weight (kg) | 82,5 | 99 | 103 | 103 | 123 | 123 |
| Gross dimensions (W × H × D) (mm) | 1200 × 425 × 865 | 1260 × 982 × 488 | 1260 × 982 × 488 | 1260 × 982 × 488 | 1285 × 1040 × 495 | 1285 × 1040 × 495 |
| Gross weight (kg) | 96 | 114 | 126 | 126 | 145 | 145 |
Measurement conditions: ¹ Heating: outdoor temp. 7°C DB, 85% R.H.; water inlet/outlet temp. 30°C/35°C (according to EN14511). ² Heating: outdoor temp. 7°C DB, 85% R.H.; water inlet/outlet temp. 40°C/45°C (according to EN14511). ³ Heating: outdoor temp. 7°C DB, 85% R.H.; water inlet/outlet temp. 47°C/55°C (according to EN14511). ⁴ Cooling: outdoor temp. 35°C DB, 85% R.H.; water inlet/outlet temp. 23°C/18°C (according to EN14511). ⁵ Cooling: outdoor temp. 35°C DB, 85% R.H.; water inlet/outlet temp. 12°C/7°C (according to EN14511). ⁶ Noise level test in accordance with standard EN12102-1.