Heat pump – KAISAI – KHC-16RY3-B – monoblock – 16 kW

SKU: F140026 EAN: 2010000044032
Manufacturer

Net width

Net depth

Net height

Model

CN 84186100
Price 1 987,95 €
Incl. VAT

1 987,95 €
Incl. VAT

In stock:

6 pcs
Log in to place an order

1 987,95 €
Incl. VAT

In stock:

6 pcs
Log in to place an order

Product details

Manufacturer

Net width

Net depth

Net height

Model

CN 84186100

KAISAI KHC-06RY1-B – KHC-16RY3-B

The series of modern KAISAI monoblock air-to-water heat pumps are highly efficient units designed for comprehensive space heating, cooling and domestic hot water production. Using the environmentally friendly refrigerant R32 and advanced inverter technology, these systems provide stable and efficient operation even in challenging climatic conditions. The units feature high seasonal energy efficiency classes (A+++ or A++ depending on the supply temperature and model variant).

Key features of KAISAI KHC-06RY1-B – KHC-16RY3-B:

  • Wide power range: Nominal heating capacity depending on model ranges from 5.7 to 15.2 kW, allowing selection of the ideal unit for the building’s demand.
  • High energy efficiency: Space heating energy efficiency class A+++ or A++ and high seasonal efficiency ratings help reduce electricity bills.
  • Eco-friendly refrigerant R32: A modern and more environmentally friendly refrigerant with high thermodynamic properties.
  • Operation in extreme temperatures: Reliable heating operation at ambient temperatures from -25 to 35 °C.
  • Versatile application: The unit supports heating, cooling and domestic hot water (DHW) production up to temperatures of 43 °C.
  • Compact monoblock design: Robust outdoor unit containing the complete hydraulic and refrigeration system with a net weight from 86 to 144 kg.

Who is this a good choice for?

KAISAI Monoblock heat pumps are an excellent choice for owners of single-family homes and commercial buildings who seek an independent, energy-efficient and environmentally friendly source of heating and cooling. Thanks to flexible power supply options (variants 1N-230V and 3N-400V) and a wide power range from 6 to 16 kW, the system is suitable for both new-build and renovated properties that require stable operation at low outdoor temperatures.

Parameter KHC-06RY1-B KHC-08RY3-B KHC-10RY3-B KHC-12RY3-B KHC-14RY3-B KHC-16RY3-B
Product fiche (EU Regulation No. 811/2013)
Temperate climate
Seasonal space heating energy efficiency class (35°C) A+++ A+++ A+++ A+++ A+++ A+++
Seasonal space heating energy efficiency class (55°C) A++ A++ A++ A++ A++ A++
Nominal heating capacity (35°C) (kW) 6,6 8,1 9,2 12,0 13,7 15,2
Nominal heating capacity (55°C) (kW) 5,7 6,8 7,7 11,6 12,1 13,0
Seasonal space heating energy efficiency (35°C) (%) 195,0 205,6 204,8 189,3 185,6 181,6
Seasonal space heating energy efficiency (55°C) (%) 131,5 137,9 136,6 135,1 135,6 133,2
Annual energy consumption (35°C) (kWh) 2845 3218 3644 5153 6013 6805
Annual energy consumption (55°C) (kWh) 3345 4056 4539 6928 7203 7896
Sound power level Lwa (dB) 58 59 60 65 65 68
Colder climate
Nominal heating capacity (35°C) – colder climate (kW) 5,6 7,0 7,7 11,4 12,6 13,7
Nominal heating capacity (55°C) – colder climate (kW) 4,3 5,8 6,7 10,3 11,0 11,8
Seasonal space heating energy efficiency (35°C) – colder climate (%) 165,3 170,0 169,8 160,2 159,6 157,8
Seasonal space heating energy efficiency (55°C) – colder climate (%) 111,1 112,0 116,4 117,7 118,9 121,8
Annual energy consumption (35°C) – colder climate (kWh) 3300 3976 4423 6871 7667 8431
Annual energy consumption (55°C) – colder climate (kWh) 3681 4950 5540 8420 8867 9310
Warmer climate
Nominal heating capacity (35°C) – warmer climate (kW) 6,1 8,1 8,6 11,1 12,1 13,1
Nominal heating capacity (55°C) – warmer climate (kW) 5,1 7,6 8,6 12,5 13,7 13,8
Seasonal space heating energy efficiency (35°C) – warmer climate (%) 259,8 276,6 280,5 255,6 259,8 248,1
Seasonal space heating energy efficiency (55°C) – warmer climate (%) 164,7 175,8 180,3 173,8 176,4 175,9
Annual energy consumption (35°C) – warmer climate (kWh) 1244 1551 1617 2296 2462 2786
Annual energy consumption (55°C) – warmer climate (kWh) 1640 2259 2516 3780 4092 4116
Technical data
Type of heat pump Air-to-water monoblock heat pump Air-to-water monoblock heat pump Air-to-water monoblock heat pump Air-to-water monoblock heat pump Air-to-water monoblock heat pump Air-to-water monoblock heat pump
Power supply 1N-230V 50Hz 3N 400V 50Hz 3N 400V 50Hz 3N 400V 50Hz 3N 400V 50Hz 3N 400V 50Hz
Maximum current of the outdoor unit (MCA) (A) 27 29 30 23 24 25
Refrigerant quantity (R32) (kg) 1,40 1,40 1,40 1,75 1,75 1,75
External dimensions (W × H × D) (mm) 1295 × 718 × 429 1295 × 718 × 429 1295 × 718 × 429 1385 × 865 × 526 1385 × 865 × 526 1385 × 865 × 526
Net weight (kg) 86 105 105 144 144 144
Outdoor temperature range – heating (°C) -25 to 35 -25 to 35 -25 to 35 -25 to 35 -25 to 35 -25 to 35
Outdoor temperature range – cooling (°C) -5 to 43 -5 to 43 -5 to 43 -5 to 43 -5 to 43 -5 to 43
Outdoor temperature range – DHW (°C) -25 to 43 -25 to 43 -25 to 43 -25 to 43 -25 to 43 -25 to 43

The maximum noise level is less than 70 dB(A) for both the hydraulic unit and the outdoor unit (in accordance with IEC 704-1 and ISO 3744 standards).