SOLAX Battery TP-HS50E

SKU: F20S323 EAN: 2010000035054
Manufacturer

Capacity

Number of charging cycles

Battery cell type

LiFePO4

Module voltage

Charging current

Discharge current

Required number of modules

Depth of Discharge

Warranty

Net width

Net depth

Net height

Weight 48,28 kg
CN 85076000
Price 1 693,02 
Gross

1 693,02 
Gross

In stock:

15 pcs
Login to place an order

1 693,02 
Gross

In stock:

15 pcs
Login to place an order

Datasheet Solax X3-IES-5K - X3-IES-15K Solax-X3-IES-5K-X3-IES-15K-Datasheet.pdf Manual Solax X3-IES-5K - X3-IES-15K Solax-X3-IES-5K-X3-IES-15K-Manual.pdf

Product details

Manufacturer

Capacity

Number of charging cycles

Battery cell type

LiFePO4

Module voltage

Charging current

Discharge current

Required number of modules

Depth of Discharge

Warranty

Net width

Net depth

Net height

Weight 48,28 kg
CN 85076000

SOLAX TP-HS50E Battery

The Solax X3-IES is an integrated home energy storage system (ESS) offering intelligent energy management, high efficiency, and reliability. Designed for flexibility and easy adaptation, it provides optimal energy harvesting and microgrid support, making it an ideal solution for modern households.

Key features of the Solax X3-IES:

  • Intelligent energy management with AI compatibility and production/consumption forecasting.
  • Microgrid support enabling real-time grid balancing and off-grid operation.
  • High efficiency thanks to global MPP scanning and dual charging/discharging capabilities.
  • IP66 protection rating and Type II SPD protection on both the AC and DC sides for increased reliability.
  • Flexibility with a plug-and-play design and support for a maximum DC input of 20 A.
  • Long battery life of over 6,000 cycles and a 10-year warranty.

Who is this a good choice for?

The Solax X3-IES system is intended for homeowners seeking an advanced, integrated energy storage solution. It’s ideal for those who want to optimize solar energy use, increase energy independence, and take advantage of intelligent load-management features such as heat pumps or EV chargers. With its reliability and high performance, this system works well in both new installations and retrofit residential projects.

Datasheet Solax X3-IES-5K - X3-IES-15K Solax-X3-IES-5K-X3-IES-15K-Datasheet.pdf Manual Solax X3-IES-5K - X3-IES-15K Solax-X3-IES-5K-X3-IES-15K-Manual.pdf

Parameter 4 / 5 / 6 / 8 / 10 / 12 / 15 kW
Integrated Home Energy Storage System (ESS)
Battery Specification
Number of batteries 2 3 4 5 6
Rated capacity 10.2 kWh 15.3 kWh 20.4 kWh 25.6 kWh 30.7 kWh
Usable energy 9.2 kWh 13.8 kWh 18.4 kWh 23.0 kWh 27.6 kWh
Max. operating power 10.2 kW 15.0 kW 15.0 kW 15.0 kW 15.0 kW
Max. charge / discharge current 50 A 50 A 50 A 50 A 50 A
Cycle life > 6000 cycles > 6000 cycles > 6000 cycles > 6000 cycles > 6000 cycles
Battery type Lithium-ion (LFP) Lithium-ion (LFP) Lithium-ion (LFP) Lithium-ion (LFP) Lithium-ion (LFP)
Nominal capacity / cell capacity④ 5.1 Ah / 50 Ah 5.1 Ah / 50 Ah 5.1 Ah / 50 Ah 5.1 Ah / 50 Ah 5.1 Ah / 50 Ah
Usable energy⑤ 4.6 kWh 4.6 kWh 4.6 kWh 4.6 kWh 4.6 kWh
Standard power 3 kW 3 kW 3 kW 3 kW 3 kW
Max. Power 5.1 kW 5.1 kW 5.1 kW 5.1 kW 5.1 kW
Max. charge / discharge current⑥ 50 A 50 A 50 A 50 A 50 A
Warranty 10 years 10 years 10 years 10 years 10 years
Dimensions TBMS-MCS0800E (W x H x D) / Weight 730 x 165 x 150 mm / 9.3 kg 730 x 165 x 150 mm / 9.3 kg 730 x 165 x 150 mm / 9.3 kg 730 x 165 x 150 mm / 9.3 kg 730 x 165 x 150 mm / 9.3 kg
Dimensions TP-HS50E (W x H x D) / Weight 730 × 318 × 150 mm / 47 kg 730 × 318 × 150 mm / 47 kg 730 × 318 × 150 mm / 47 kg 730 × 318 × 150 mm / 47 kg 730 × 318 × 150 mm / 47 kg
Parameter X3-IES-4K X3-IES-5K X3-IES-6K X3-IES-8K X3-IES-10K X3-IES-12K X3-IES-15K
Inverter Specification
Rated output power 4 kW 5 kW 6 kW 8 kW 10 kW 12 kW 15 kW
Max. recommended PV array power 8 kWp 10 kWp 12 kWp 16 kWp 20 kWp 24 kWp 30 kWp
Max. PV input voltage① 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Rated PV input voltage 600 V 600 V 600 V 600 V 600 V 600 V 600 V
Operating voltage range 90-950 V 90-950 V 90-950 V 90-950 V 90-950 V 90-950 V 90-950 V
MPPT voltage range 110 – 950 V 110 – 950 V 110 – 950 V 110 – 950 V 110 – 950 V 110 – 950 V 110 – 950 V
Start-up voltage 140 V 140 V 140 V 140 V 140 V 140 V 140 V
Number of MPP trackers / strings per tracker 2/(1/1) 2/(2/1) 2/(2/1) 2/(2/1) 2/(2/1) 2/(2/1) 2/(2/1)
Max. input current per MPPT (MPPT1/2) 20 A / 20 A 32 A / 20 A 32 A / 20 A 32 A / 20 A 32 A / 20 A 32 A / 20 A 32 A / 20 A
Max. short-circuit input current per MPPT (MPPT1/2) 25 A / 25 A 40 A / 25 A 40 A / 25 A 40 A / 25 A 40 A / 25 A 40 A / 25 A 40 A / 25 A
AC Input and Output (Grid)
Rated output power 4000 W 5000 W 6000 W 8000 W 10000 W 12000 W 15000 W
Rated output current 5.8 A 7.3 A 8.7 A 11.6 A 14.5 A 17.4 A 21.8 A
Max. output apparent power 4000 VA 5500 VA 6600 VA 8800 VA 10000 VA 12000 VA 15000 VA
Max. continuous output current 5.8 A 8.0 A 9.6 A 12.8 A 14.5 A 19.2 A 24.0 A
Rated AC voltage 3/N/PE, 230 / 400 V 3/N/PE, 230 / 400 V 3/N/PE, 230 / 400 V 3/N/PE, 230 / 400 V 3/N/PE, 230 / 400 V 3/N/PE, 230 / 400 V 3/N/PE, 230 / 400 V
Max. AC input apparent power 10 kVA 10 kVA 12 kVA 16 kVA 20 kVA 20 kVA 20 kVA
Max. AC input current 16.1 A 16.1 A 19.3 A 25.8 A 32.0 A 32.0 A 32.0 A
Rated AC frequency 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
AC frequency range③ 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz 50 ± 5 Hz / 60 ± 5 Hz
Power factor range –1 (0.8 lagging to 0.8 leading) –1 (0.8 lagging to 0.8 leading) –1 (0.8 lagging to 0.8 leading) –1 (0.8 lagging to 0.8 leading) –1 (0.8 lagging to 0.8 leading) –1 (0.8 lagging to 0.8 leading) –1 (0.8 lagging to 0.8 leading)
THDi (rated power) <3% <3% <3% <3% <3% <3% <3%
EPS Output (Off-grid) (with battery)
Rated EPS output power 4 kVA 5 kVA 6 kVA 8 kVA 10 kVA 12 kVA 15 kVA
Peak EPS output power 2× rated power, 10 s. 2× rated power, 10 s. 2× rated power, 10 s. 2× rated power, 10 s. 2× rated power, 10 s. 2× rated power, 10 s. 2× rated power, 10 s.
Transfer time < 10 ms < 10 ms < 10 ms < 10 ms < 10 ms < 10 ms < 10 ms
Rated EPS output voltage, frequency 230 V / 400 V, 50 Hz / 60 Hz 230 V / 400 V, 50 Hz / 60 Hz 230 V / 400 V, 50 Hz / 60 Hz 230 V / 400 V, 50 Hz / 60 Hz 230 V / 400 V, 50 Hz / 60 Hz 230 V / 400 V, 50 Hz / 60 Hz 230 V / 400 V, 50 Hz / 60 Hz
Efficiency
Max. efficiency 98.0% 98.0% 98.0% 98.0% 98.0% 98.0% 98.0%
European efficiency 97.7% 97.7% 97.7% 97.7% 97.7% 97.7% 97.7%
Environmental Limits
Protection rating IP66 IP66 IP66 IP66 IP66 IP66 IP66
Operating ambient temperature range -35–60°C (derating above 45°C) -35–60°C (derating above 45°C) -35–60°C (derating above 45°C) -35–60°C (derating above 45°C) -35–60°C (derating above 45°C) -35–60°C (derating above 45°C) -35–60°C (derating above 45°C)
Max. operating altitude 3000 m 3000 m 3000 m 3000 m 3000 m 3000 m 3000 m
Relative humidity 0-100% RH (condensing) 0-100% RH (condensing) 0-100% RH (condensing) 0-100% RH (condensing) 0-100% RH (condensing) 0-100% RH (condensing) 0-100% RH (condensing)
Overvoltage category Power grid: III, Battery: II, PV: II Power grid: III, Battery: II, PV: II Power grid: III, Battery: II, PV: II Power grid: III, Battery: II, PV: II Power grid: III, Battery: II, PV: II Power grid: III, Battery: II, PV: II Power grid: III, Battery: II, PV: II
General
Dimensions (W x H x D) 730 x 1281 × 209.5 mm 730 × 1281 × 209.5 mm 730 × 1599 × 209.5 mm 730 x 1281 × 209.5 mm 730 × 1599 × 209.5 mm 730 x 1281 × 209.5 mm 730 × 1599 × 209.5 mm
Net weight 144.2 kg 144.2 kg / 100.5 kg 191.2 kg / 147.5 kg 144.2 kg / 147.5 kg 191.2 kg / 147.5 kg 144.2 kg / 147.5 kg 191.2 kg / 147.5 kg
Cooling method Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling
Communication interfaces RS485, CAN, DO, DI RS485, CAN, DO, DI RS485, CAN, DO, DI RS485, CAN, DO, DI RS485, CAN, DO, DI RS485, CAN, DO, DI RS485, CAN, DO, DI
Power consumption (night) <40 W in warm standby, <5 W in cold standby <40 W in warm standby, <5 W in cold standby <40 W in warm standby, <5 W in cold standby <40 W in warm standby, <5 W in cold standby <40 W in warm standby, <5 W in cold standby <40 W in warm standby, <5 W in cold standby <40 W in warm standby, <5 W in cold standby
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Protection
Protections Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring Surge protection, DC reverse polarity protection, residual current detection, over-temperature protection, DC isolation protection, grid monitoring, DC injection monitoring, backfeed current monitoring
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II
Arc fault circuit interrupter (AFCI) Optional Optional Optional Optional Optional Optional Optional

Official distribution