SOLAX TRENE-P125B261L
| Manufacturer | |
|---|---|
| Net depth | |
| Number of charging cycles | |
| Rated power | |
| Capacity | |
| Net width | |
| Net height | |
| Warranty |
Gross
Product details
| Manufacturer | |
|---|---|
| Net depth | |
| Number of charging cycles | |
| Rated power | |
| Capacity | |
| Net width | |
| Net height | |
| Warranty |
Order lead time is 60/90 days
SolaX Power ESS-TRENE Energy Storage System (125 kW / 261 kWh) with Liquid Cooling
The SolaX Power ESS-TRENE energy storage system with liquid cooling is an advanced, AC-connected solution designed for high performance and reliability in commercial and industrial applications. The 125 kW / 261 kWh system uses Premium LFP batteries, offering high power density, intelligent management and scalability to the megawatt-hour level. With a compact design and optimized space utilization, the ESS-TRENE is an ideal choice for demanding projects.
Key features of the SolaX Power ESS-TRENE Energy Storage System:
- High power and capacity: The system delivers a rated power of 125 kW and a battery capacity of 261 kWh (LFP 314Ah), with the possibility to scale to megawatt-hours.
- Advanced LFP technology and long life: Use of Premium LFP batteries ensures over 8,000 life cycles (at 0.25C, EOL 70%), providing long-term, reliable operation.
- Intelligent management and remote monitoring: Advanced energy management system (EMS/BMS) developed by SolaX, VPP readiness (SolaX Cloud, OpenADR), microgrid support, and remote monitoring and maintenance 24/7.
- Comprehensive safety and efficient liquid cooling: 4+1 fire safety design, battery fire suppression package with aerosol (optional Novec1230/water), IP66 rating for the inverter and IP55 for the cabinet, and efficient liquid cooling.
- Adaptability and high efficiency: Supports on-grid and off-grid operation, maximum system efficiency up to 98%, and optimized space utilization.
Who is this a good choice for?
The SolaX Power ESS-TRENE energy storage system is an excellent solution for the commercial & industrial (C&I) sector, large-scale energy storage project developers, and microgrid operators. Its high power, capacity, scalability, advanced management and safety features, and efficient liquid cooling make it ideal for optimizing energy consumption, ensuring power stability, integrating with renewable energy sources, and participating in VPP programs. It is a reliable and efficient solution for demanding energy applications.
| Parameter | ESS-TRENE (TRENE-P125B261L-E) | X3-TRENE-125K (Inverter) | TB-HR522 (ESS C&I Cabinet Set) |
|---|---|---|---|
| AC INPUT AND OUTPUT (ON GRID) | |||
| Rated AC power (kW) | 125 | 125 | |
| Rated AC current (A) | 181.2 | 181.2 | |
| Max. output apparent power (kVA) | 137.5 | 137.5 | |
| Max. continuous output current (A) | 208.3 | 208.3 | |
| Rated AC voltage (V) | 400 | 3/(N)/PE, 230/400 V; 3/(N)/PE, 220/380 V | |
| Rated AC frequency (Hz) | 50 Hz / 60 Hz | 50 Hz / 60 Hz | |
| Adjustable power factor range | – 1 (0.8 lagging to 0.8 leading) | – 1 (0.8 lagging to 0.8 leading) | |
| THDi (Rated Power) (%) | < 3% | < 3% | |
| BATTERY | |||
| Battery type | LFP 314Ah | Lithium-ion | LFP 314Ah |
| Battery capacity (kWh) | 261 | 52.2 | |
| Battery configuration | 1P52S | ||
| Battery nominal voltage (V) | 832 | 650 – 936 | 166.4 |
| Battery voltage range (V) | 650 – 936 | 130 – 187.2 | |
| Max. charge/discharge current (A) | 160 | 160 | |
| Cycle life ¹ | >8000 | ||
| GENERAL | |||
| Max. efficiency (%) | 98% | 98% | |
| Dimensions (W × D × H) (mm) | 1350 × 1350 × 2355 | 880 x 665 x 310 | |
| Weight (kg) | 2810 | 95 | 330 |
| Operating ambient temperature range (°C) | -30 – 55°C | -35 – 60°C | |
| Relative humidity (%) | 0 – 95% RH | 0 – 95% RH | 0 – 95% RH (non-condensing) |
| Max. operating altitude (m) | 3000 | 3000 | 3000 |
| Cooling concept | Liquid cooling | Intelligent air cooling | |
| Ingress protection (IP) | IP55 | IP66 | IP67 |
| Fire protection | Aerosol (optionally: Novec1230) / Water | ||
| Topology | Non-isolated | ||
| Communication interfaces | RS485, CAN, Ethernet, DI | ||
| Communication with PCS | CAN | ||
| PROTECTION | |||
| Protections (Inverter) | Over/under voltage protection, DC reverse polarity protection, Residual current detection, Anti-islanding protection | ||
| Surge protection (AC) (Inverter) | Type II | ||
| CERTIFICATIONS AND APPROVALS | |||
| Certifications and approvals (ESS-TRENE) | IEC62619, IEC63056, IEC61000, IEC62477-1, UN38.3, VDE 2510-50, EN 50549 | ||
| Safety (Inverter) | EN/IEC62477 | ||
| EMC (Inverter) | EN61000-6-2/4, EN61000-3-11/12, EN5011, EC62920 | ||
| Certification (Inverter) | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA, MEA, NRS-097-2-1, RD1699, TOR |
① Rating for 8000 cycles at 0.25C with EOL at 70% capacity (for ESS-TRENE).
Notes for X3-TRENE-125K (Inverter):
① The maximum input voltage is the upper limit of DC voltage. Any higher DC input voltage will likely damage the inverter.
② Input voltage exceeding the MPPT voltage range may trigger inverter protection.
③ Isc (short-circuit current) for a single PV input string is 35 A.