SUNNIC Distributed DC Fast Charger with 6 Terminals, 360 kW
Gross
Product details
Fast DC Charging Stations SUNNIC (360-480kW)
SUNNIC fast DC charging stations with 360kW and 480kW power are technologically advanced solutions designed for efficient, high-speed charging of electric vehicles. They feature a modular design, flexible power distribution and the ability to serve multiple terminals simultaneously. These stations are suitable for indoor and outdoor use (IP54), offering high performance and reliability.
Key features of SUNNIC Fast DC Charging Stations (360-480kW):
- High charging power: Available in nominal power ratings of 360kW and 480kW, providing ultra-fast charging for electric vehicles.
- Flexible terminal configuration: Can support up to 3 terminals with dual plugs or 6 terminals with single plugs (for the 360kW model) and accordingly up to 4 or 8 terminals (for the 480kW model).
- Intelligent power distribution: Advanced power distribution strategy that allows flexible allocation of power to individual charging plugs based on needs (e.g., 40kW/80kW/120kW/160kW/200kW/240kW per plug).
- Wide output voltage range: Supports voltages from 100VDC to 1000VDC, ensuring compatibility with most electric vehicles.
- High efficiency and accuracy: Voltage and current stabilization accuracy of ≤±0.5% and power factor ≥0.99, delivering effective and precise charging.
- Resistance to environmental conditions: Operates in temperatures from -20°C to +50°C, rated IP54 and capable of working at altitudes up to 2000m without loss of performance.
Who is this a good choice for?
SUNNIC fast DC charging stations (360–480kW) are ideal for operators of public and private charging stations, electric vehicle fleets, shopping centers, parking facilities and other high-traffic locations where fast, efficient charging of multiple vehicles at once is essential. Their modular design, flexible configuration and intelligent power management make them an excellent option for expanding EV charging infrastructure.
| Parameter | 360kW | 480kW |
|---|---|---|
| Basic specifications | ||
| Rated power (kW) | 360 | 480 |
| Cooling method | Forced air cooling | Forced air cooling |
| Network type | Ethernet/4G | Ethernet/4G |
| Operating environment | Indoor or outdoor (IP54) | Indoor or outdoor (IP54) |
| Dimensions (W x D x H) (mm) | Main unit: 1200 x 900 x 1950 Terminal: 450 x 200 x 1500 (Same size for single and double plugs) |
Main unit: 2100 x 900 x 2100 Terminal: 450 x 200 x 1500 (Same size for single and double plugs) |
| Weight (kg) | Main unit: 590 Terminal: 100 (double plugs), 80 (single plugs) |
Main unit: 900 Terminal: 100 (double plugs), 80 (single plugs) |
| Input characteristics | ||
| Input voltage | 380VAC±15%, three-phase + N + PE | 380VAC±15%, three-phase + N + PE |
| Frequency (Hz) | 45-65 | 45-65 |
| Rated input current (A) | 582 | 773 |
| Power factor | ≥0.99 | ≥0.99 |
| iTHD (%) | ≤5 | ≤5 |
| Output characteristics | ||
| Voltage range (VDC) | 100-1000 | 100-1000 |
| Output current error | ≤±0.5% | ≤±0.5% |
| Voltage stabilization accuracy | ≥30A, ≤±1%; <30A, ≤±0.3A | ≥30A, ≤±1%; <30A, ≤±0.3A |
| Current regulation accuracy | ≤±0.5% | ≤±0.5% |
| Peak voltage ripple factor | ≤±1% | ≤±1% |
| Output voltage error | ≤±1% | ≤±1% |
| Maximum number of connected terminals | (terminal with double plug: 3) or (terminal with single plug: 6) | (terminal with double plug: 4) or (terminal with single plug: 8) |
| Power distribution strategy | 1. A total of 9 modules of 40kW each, divided into 6 groups, with a flexible power strategy: “40kW+80kW+40kW+80kW+40kW+80kW”. 2. Can connect up to 3 terminals with double plugs or 6 terminals with single plugs, totaling 6 plugs; the output of each module can be directed to any plug. 3. When 6 plugs are charging simultaneously, the power distribution is: 40kW+80kW+40kW+80kW+40kW+80kW. 4. Output power range per plug: 40kW/80kW/120kW/160kW/200kW/240kW. |
1. A total of 12 modules of 40kW each, divided into 8 groups, with a flexible power strategy: “40kW+80kW+40kW+80kW+40kW+80kW+40kW+80kW”. 2. Can connect up to 4 terminals with double plugs or 8 terminals with single plugs, totaling 8 plugs; the output of each module can be directed to any plug. 3. When 8 plugs are charging simultaneously, the power distribution is: 40kW+80kW+40kW+80kW+40kW+80kW+40kW+80kW. 4. Output power range per plug: 40kW/80kW/120kW/160kW/200kW/240kW. |
| Environmental specifications | ||
| Operating temperature (°C) | -20 ~ +50 | -20 ~ +50 |
| Storage temperature (°C) | -40 ~ +80 | -40 ~ +80 |
| Relative humidity | 5–90% RH, non-condensing | 5–90% RH, non-condensing |
| Operating altitude (m) | 2000m without power derating; >2000m, operating temperature decreases by 1°C for every 100m increase in altitude | 2000m without power derating; >2000m, operating temperature decreases by 1°C for every 100m increase in altitude |