Inverter – FELICITY – IVGM25KHP3G3 – hybrid – AFCI – HV

SKU: F20UD EAN: 2010000046180
Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type III

SPD Type I+II

SPD – Free slot

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

Price 1 563,53 €
Incl. VAT

1 563,53 €
Incl. VAT

Delivery time: 7 days

In stock:

6 pcs
Log in to place an order

1 563,53 €
Incl. VAT

Delivery time: 7 days

In stock:

6 pcs
Log in to place an order

Datasheet Felicity IVGM25KHP3G3 Felicity-IVGM25KHP3G3-Datasheet.pdf Manual Felicity IVGM8KHP3G3 - IVGM25KHP3G3 Felicity-IVGM8KHP3G3-IVGM25KHP3G3-Manual.pdf Certificate of compliance Felicity IVGM8KHP3G3 - IVGM25KHP3G3 Felicity-IVGM8KHP3G3-IVGM25KHP3G3-Certificate-of-compliance.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

Off-grid mode

MPPT

CAN

CAN 2.0

RS485

SPD Type I

SPD Type II

SPD Type III

SPD Type I+II

SPD – Free slot

AFCI

MPPT voltage range

Maximum input current per MPPT [A]

Maximum input power [W]

Felicity solar Series IVGM

The three-phase hybrid inverter of the IVGM series with power from 8 kW to 25 kW is an advanced high-voltage device dedicated to modern photovoltaic installations. It offers comprehensive energy management, compatibility with LFP batteries (LiFePO4), and a high enclosure protection rating of IP66, ensuring reliable operation in harsh environmental conditions. With parallel operation capability of up to 12 units, the inverter is ideal for demanding residential and commercial applications.

Key features of the IVGM Series:

  • Wide power range: Available variants from 8 kW to 25 kW with support for charging and discharging currents up to 50A/50A.
  • Safety and protection: IP66 protection rating and comprehensive electrical protections, including arc fault detection (AFCI).
  • System flexibility: Compatibility with generators, smart loads and microinverters, as well as the ability to operate in parallel up to 12 units.
  • Remote monitoring: Convenient system management and control via the dedicated Fsolar APP and Wi-Fi module.
  • High field performance: Adapted to operate across a wide temperature range from -40 to 60 °C with intelligent cooling technology.

Who is this a good choice for?

The IVGM Series is an excellent choice for homeowners and commercial facility owners looking for an efficient three-phase hybrid inverter with the option to expand the system with energy storage. It provides energy independence, secure emergency power supply and full control over energy consumption thanks to advanced time-of-use management functions (Time of Use).

Datasheet Felicity IVGM25KHP3G3 Felicity-IVGM25KHP3G3-Datasheet.pdf Manual Felicity IVGM8KHP3G3 - IVGM25KHP3G3 Felicity-IVGM8KHP3G3-IVGM25KHP3G3-Manual.pdf Certificate of compliance Felicity IVGM8KHP3G3 - IVGM25KHP3G3 Felicity-IVGM8KHP3G3-IVGM25KHP3G3-Certificate-of-compliance.pdf

Parameter IVGM8KHP3G3 IVGM9K9HP3G3 IVGM10KHP3G3 IVGM12KHP3G3 IVGM15KHP3G3 IVGM20KHP3G3 IVGM25KHP3G3
Battery input data
Battery voltage range (Vdc) 160–700 Vdc 160–700 Vdc 160–700 Vdc 160–700 Vdc 160–700 Vdc 160–700 Vdc 160–700 Vdc
Max. charging and discharging current (A) 50 A / 50 A 50 A / 50 A 50 A / 50 A 50 A / 50 A 50 A / 50 A 50 A / 50 A 50 A / 50 A
Max. charging and discharging power (kW) 8 kW 9,9 kW 10 kW 12 kW 15 kW 20 kW 25 kW
Battery type LFP (LiFePO4) LFP (LiFePO4) LFP (LiFePO4) LFP (LiFePO4) LFP (LiFePO4) LFP (LiFePO4) LFP (LiFePO4)
DC input data (PV side)
Max. DC input power (kW) 16 kW 19,8 kW 20 kW 24 kW 30 kW 40 kW 50 kW
Max. DC input voltage (Vdc) 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc
Start-up voltage (Vdc) 180 Vdc 180 Vdc 180 Vdc 180 Vdc 180 Vdc 180 Vdc 180 Vdc
MPPT voltage range (Vdc) 150–850 Vdc 150–850 Vdc 150–850 Vdc 150–850 Vdc 150–850 Vdc 150–850 Vdc 150–850 Vdc
Rated DC input voltage (Vdc) 600 Vdc 600 Vdc 600 Vdc 600 Vdc 600 Vdc 600 Vdc 600 Vdc
PV input current (A) 21 A + 21 A 21 A + 21 A 21 A + 21 A 21 A + 21 A 42 A + 21 A 42 A + 42 A 42 A + 42 A
Number of MPP trackers / Number of strings per MPP tracker 2 / 1+1 2 / 1+1 2 / 1+1 2 / 1+1 2 / 2+1 2 / 2+2 2 / 2+2
Grid data
Rated input voltage 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%)
Rated grid frequency (Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz)
Max. apparent AC input/output power (kVA) 8,8 kVA 9,9 kVA 11 kVA 13,2 kVA 16,5 kVA 22 kVA 27,5 kVA
Rated AC input/output current (A) [1] 11,6 A 14,3 A 14,5 A 17,4 A 21,7 A 29 A 36,3 A
Max. output current (A) 12,8 A 14,3 A 16 A 19,2 A 23,8 A 32 A 39,8 A
Max. continuous AC throughput (A) 40 A 40 A 40 A 40 A 40 A 80 A 80 A
AC output data (backup power)
Rated output power (kW) 8 kW 9,9 kW 10 kW 12 kW 15 kW 20 kW 25 kW
Max. AC current (A) [2] 12,8 A 14,3 A 16 A 19,2 A 23,8 A 32 A 39,8 A
Peak power (island mode) (kW) 12 kW (1,5× rated power, 10 s) 14,9 kW (1,5× rated power, 10 s) 15 kW (1,5× rated power, 10 s) 18 kW (1,5× rated power, 10 s) 22,5 kW (1,5× rated power, 10 s) 30 kW (1,5× rated power, 10 s) 37,5 kW (1,5× rated power, 10 s)
Rated AC output voltage 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%) 220/380 Vac, 230/400 Vac (-20%~+15%)
Rated AC output frequency (Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz) 50/60 Hz (45–55 Hz / 55–65 Hz)
Protections
DC reverse polarity protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated
AC output overcurrent protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated
AC output overvoltage protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated
AC output short-circuit protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Thermal protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated
DC terminal insulation resistance monitoring Integrated Integrated Integrated Integrated Integrated Integrated Integrated
DC component monitoring Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Residual/ground differential current monitoring Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Arc fault circuit interrupter (AFCI) Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Grid monitoring Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Anti-islanding protection Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Ground fault detection Integrated Integrated Integrated Integrated Integrated Integrated Integrated
DC input switch Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Protection against load disconnection during overvoltage Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Residual current detection (RCD) Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Surge protection level TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC) TYP II (DC), TYP II (AC)
General data
Operating temperature range (°C) -40 to 60 °C (>45 °C power derating) -40 to 60 °C (>45 °C power derating) -40 to 60 °C (>45 °C power derating) -40 to 60 °C (>45 °C power derating) -40 to 60 °C (>45 °C power derating) -40 to 60 °C (>45 °C power derating) -40 to 60 °C (>45 °C power derating)
Pollution degree PD2 (indoor), PD3 (outdoor) PD2 (indoor), PD3 (outdoor) PD2 (indoor), PD3 (outdoor) PD2 (indoor), PD3 (outdoor) PD2 (indoor), PD3 (outdoor) PD2 (indoor), PD3 (outdoor) PD2 (indoor), PD3 (outdoor)
Protection class Class I Class I Class I Class I Class I Class I Class I
Voltage classification DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2
Protection rating IP66 IP66 IP66 IP66 IP66 IP66 IP66
Cooling method Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
BMS communication CAN / RS485 CAN / RS485 CAN / RS485 CAN / RS485 CAN / RS485 CAN / RS485 CAN / RS485
Topology Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless
Monitoring module Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi
Display LCD + LED LCD + LED LCD + LED LCD + LED LCD + LED LCD + LED LCD + LED
Mounting method Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted
Warranty 5 years / 10 years 5 years / 10 years 5 years / 10 years 5 years / 10 years 5 years / 10 years 5 years / 10 years 5 years / 10 years
Grid standards NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129
Safety and EMC standards IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Net weight (kg) 39,4 kg 39,4 kg 39,4 kg 39,4 kg 39,4 kg 39,4 kg 39,4 kg
Gross weight (kg) 48,6 kg 48,6 kg 48,6 kg 48,6 kg 48,6 kg 48,6 kg 48,6 kg
Product dimensions (W × H × D) (mm) 642 × 445 × 237,5 mm 642 × 445 × 237,5 mm 642 × 445 × 237,5 mm 642 × 445 × 237,5 mm 642 × 445 × 237,5 mm 642 × 445 × 237,5 mm 642 × 445 × 237,5 mm
Package dimensions (W × H × D) (mm) 789 × 568 × 367 mm 789 × 568 × 367 mm 789 × 568 × 367 mm 789 × 568 × 367 mm 789 × 568 × 367 mm 789 × 568 × 367 mm 789 × 568 × 367 mm

[1], [2] Data based on rated AC voltage 230/400 Vac.