SolarEdge Inverters from the SE12.5K – SE27.6K Series
The SE12.5K – SE27.6K series of inverters from SolarEdge features advanced technology, combining high efficiency, reliability, and intelligent energy management functionalities. Perfect for commercial and industrial applications, they provide everything needed to maximize the performance of PV systems.
Key Features:
- High Efficiency: Maximum efficiency reaching up to 98.3%, ensuring effective utilization of solar energy.
- Quick Setup: Intuitive inverter setup directly from your smartphone using the SolarEdge SetApp.
- Module-Level Monitoring: Enables detailed management and analysis of the performance of each module in the system.
- Versatile Installation: IP65 certification allows for installation in both indoor and outdoor environments.
- Advanced Energy Management: SolarEdge technology provides smart functions that optimize the performance of the PV system.
Advantages of SolarEdge Inverters from the SE12.5K – SE27.6K Series:
Inverters from this series are distinguished by their exceptionally quiet operation, making them suitable for use in various environments, including near residential buildings. Equipped with a constant voltage feature, they allow for the design of longer strings, increasing the design flexibility of the PV system. Additionally, selected models such as the SE25K and SE27.6K come with optional integrated DC protection circuits, which eliminate the need for additional fuses, significantly simplifying installation.
The high reliability of these devices is achieved through advanced safety features, such as arc protection and the ability to quickly shut down in case of a fault. Ethernet or Wi-Fi connectivity, along with compatibility with SolarEdge’s intelligent energy management systems, makes these inverters an excellent choice for large commercial and industrial installations.
Technical Specification for SolarEdge SE12.5K-SE27.6K
Application for Inverters with Product Numbers | ||||||
---|---|---|---|---|---|---|
Parameter | SE12.5K | SE15K | SE16K | SE17K | SE25K | SE27.6K |
Output | ||||||
Nominal AC Power (VA) | 12500 | 15000 | 16000 | 17000 | 25000 | 27600 |
Maximum AC Power (VA) | 12500 | 15000 | 16000 | 17000 | 25000 | 27600 |
AC Output Voltage (V) | 380 / 220; 400 / 230 | 380 / 220; 400 / 230 | 380 / 220; 400 / 230 | 380 / 220; 400 / 230 | 380 / 220; 400 / 230 | 380 / 220; 400 / 230 |
AC Output Voltage Range (V) | 184 – 264.5 | 184 – 264.5 | 184 – 264.5 | 184 – 264.5 | 184 – 264.5 | 184 – 264.5 |
AC Frequency (Hz) | 50/60 ± 5 | 50/60 ± 5 | 50/60 ± 5 | 50/60 ± 5 | 50/60 ± 5 | 50/60 ± 5 |
Maximum Continuous Output Current (A) | 20 | 23 | 25.5 | 26 | 38 | 40 |
Supported Networks | 3 / N / PE (star-grounded network with neutral wire) | 3 / N / PE (star-grounded network with neutral wire) | 3 / N / PE (star-grounded network with neutral wire) | 3 / N / PE (star-grounded network with neutral wire) | 3 / N / PE (star-grounded network with neutral wire) | 3 / N / PE (star-grounded network with neutral wire) |
Network Monitoring, Islanding Protection, Power Factor | Yes | Yes | Yes | Yes | Yes | Yes |
Total Harmonic Distortion (THD) | < 3% | < 3% | < 3% | < 3% | < 3% | < 3% |
Input | ||||||
Maximum DC Power (W) | 16850 | 20250 | 21600 | 22950 | 33750 | 37250 |
Transformerless, Ungrounded | Yes | Yes | Yes | Yes | Yes | Yes |
Maximum Input Voltage (V) | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc |
Nominal Input Voltage (V) | 750 Vdc | 750 Vdc | 750 Vdc | 750 Vdc | 750 Vdc | 750 Vdc |
Maximum Input Current (A) | 21 | 22 | 23 | 23 | 37 | 40 |
Reverse Polarity Protection | Yes | Yes | Yes | Yes | Yes | Yes |
Ground Fault Detection | Sensitivity 700 kΩ | Sensitivity 700 kΩ | Sensitivity 700 kΩ | Sensitivity 700 kΩ | Sensitivity 350 kΩ | Sensitivity 350 kΩ |
Inverter Efficiency (%) | 98.0 | 98.0 | 98.0 | 98.0 | 98.3 | 98.3 |
European Efficiency (%) | 97.7 | 97.6 | 97.7 | 97.7 | 98.0 | 98.0 |
Night Consumption (W) | < 2.5 | < 2.5 | < 2.5 | < 2.5 | < 4 | < 4 |
Additional Features | ||||||
Supported Communication Interfaces | RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) | RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) | RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) | RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) | RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) | RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) |
Inverter Startup | Via the SetApp mobile application using the built-in Wi-Fi access point for local connection | Via the SetApp mobile application using the built-in Wi-Fi access point for local connection | Via the SetApp mobile application using the built-in Wi-Fi access point for local connection | Via the SetApp mobile application using the built-in Wi-Fi access point for local connection | Via the SetApp mobile application using the built-in Wi-Fi access point for local connection | Via the SetApp mobile application using the built-in Wi-Fi access point for local connection |
Intelligent Energy Management | Export Limitation | Export Limitation | Export Limitation | Export Limitation | Export Limitation | Export Limitation |
Arc Fault Protection | Integrated, user-configurable (according to UL1699B) | Integrated, user-configurable (according to UL1699B) | Integrated, user-configurable (according to UL1699B) | Integrated, user-configurable (according to UL1699B) | Integrated, user-configurable (according to UL1699B) | Integrated, user-configurable (according to UL1699B) |
Rapid Disconnect | Optional (Automatic upon AC grid disconnection) | Optional (Automatic upon AC grid disconnection) | Optional (Automatic upon AC grid disconnection) | Optional (Automatic upon AC grid disconnection) | Optional (Automatic upon AC grid disconnection) | Optional (Automatic upon AC grid disconnection) |
DC Protective Device (Optional) | ||||||
2-Pole Disconnect | Not Available | Not Available | Not Available | Not Available | 1000V / 40A | 1000V / 40A |
Surge Protection | Not Available | Not Available | Not Available | Not Available | Type II, replaceable | Type II, replaceable |
DC Fuses | Not Available | Not Available | Not Available | Not Available | Optional, 20A | Optional, 20A |
Compliance | Not Available | Not Available | Not Available | Not Available | UTE-C15-712-1 | UTE-C15-712-1 |
Standards Compliance | ||||||
Safety | IEC-62103 (EN50178), IEC-62109, AS3100 | IEC-62103 (EN50178), IEC-62109, AS3100 | IEC-62103 (EN50178), IEC-62109, AS3100 | IEC-62103 (EN50178), IEC-62109, AS3100 | IEC-62103 (EN50178), IEC-62109, AS3100 | IEC-62103 (EN50178), IEC-62109, AS3100 |
Grid Connection | VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW | VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW | VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW | VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW | VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW | VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW |
EMC | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 |
RoHS | Yes | Yes | Yes | Yes | Yes | Yes |
Mechanical Specification | ||||||
Diameter of AC Output Grommet / Wire Cross Section | 15-21mm / Solid wire 2.5-16 mm² | 15-21mm / Solid wire 2.5-16 mm² | 15-21mm / Solid wire 2.5-16 mm² | 15-21mm / Solid wire 2.5-16 mm² | 18-25mm / Solid wire 2.5-16 mm², Stranded wire 2.5-10 mm² | 18-25mm / Solid wire 2.5-16 mm², Stranded wire 2.5-10 mm² |
DC Input | 2 pairs of MC4 | 2 pairs of MC4 | 2 pairs of MC4 | 2 pairs of MC4 | 3 pairs of MC4 | 3 pairs of MC4 |
DC Input with DC Protection Device | Not Available | Not Available | Not Available | Not Available | Outer diameter of cable grommet 5-10 mm / Wire cross-section 0.5 – 13.5 mm² | Outer diameter of cable grommet 5-10 mm / Wire cross-section 0.5 – 13.5 mm² |
Dimensions (HxWxD) (mm) | 540 x 315 x 260 | 540 x 315 x 260 | 540 x 315 x 260 | 540 x 315 x 260 | 540 x 315 x 260 | 540 x 315 x 260 |
Dimensions with DC Protection Device (H x W x D) (mm) | Not Available | Not Available | Not Available | Not Available | 775 x 315 x 260 | 775 x 315 x 260 |
Weight (kg) | 30.7 | 30.7 | 30.7 | 30.7 | 45 | 45 |
Weight with DC Protection Device | Not Available | Not Available | Not Available | Not Available | 48 | 48 |
Operating Temperature Range (°C) | -40 to +60 | -40 to +60 | -40 to +60 | -40 to +60 | -40 to +60 | -40 to +60 |
Cooling Type | User-replaceable Fan | User-replaceable Fan | User-replaceable Fan | User-replaceable Fan | User-replaceable Fan | User-replaceable Fan |
Noise Emission (dBA) | < 50 | < 50 | < 50 | < 50 | < 55 | < 55 |
Protection Class | IP65 – suitable for outdoor or indoor use | IP65 – suitable for outdoor or indoor use | IP65 – suitable for outdoor or indoor use | IP65 – suitable for outdoor or indoor use | IP65 – suitable for outdoor or indoor use | IP65 – suitable for outdoor or indoor use |
Mounting | Bracket included | Bracket included | Bracket included | Bracket included | Bracket included | Bracket included |