Inverter – FELICITY – IVGM25KHP3G3 – hybrid – AFCI – HV
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] |
Incl. VAT
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Type III | |
| SPD Type I+II | |
| SPD – Free slot | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| Maximum input power [W] |
Felicity solar Series IVGM
The three-phase hybrid inverter of the IVGM series with power from 8 kW to 25 kW is an advanced high-voltage device dedicated to modern photovoltaic installations. It offers comprehensive energy management, compatibility with LFP batteries (LiFePO4), and a high enclosure protection rating of IP66, ensuring reliable operation in harsh environmental conditions. With parallel operation capability of up to 12 units, the inverter is ideal for demanding residential and commercial applications.
Key features of the IVGM Series:
- Wide power range: Available variants from 8 kW to 25 kW with support for charging and discharging currents up to 50A/50A.
- Safety and protection: IP66 protection rating and comprehensive electrical protections, including arc fault detection (AFCI).
- System flexibility: Compatibility with generators, smart loads and microinverters, as well as the ability to operate in parallel up to 12 units.
- Remote monitoring: Convenient system management and control via the dedicated Fsolar APP and Wi-Fi module.
- High field performance: Adapted to operate across a wide temperature range from -40 to 60 °C with intelligent cooling technology.
Who is this a good choice for?
The IVGM Series is an excellent choice for homeowners and commercial facility owners looking for an efficient three-phase hybrid inverter with the option to expand the system with energy storage. It provides energy independence, secure emergency power supply and full control over energy consumption thanks to advanced time-of-use management functions (Time of Use).
| Parameter | IVGM8KHP3G3 | IVGM9K9HP3G3 | IVGM10KHP3G3 | IVGM12KHP3G3 | IVGM15KHP3G3 | IVGM20KHP3G3 | IVGM25KHP3G3 |
|---|---|---|---|---|---|---|---|
| Battery input data | |||||||
| Battery voltage range (Vdc) | 160–700 Vdc | 160–700 Vdc | 160–700 Vdc | 160–700 Vdc | 160–700 Vdc | 160–700 Vdc | 160–700 Vdc |
| Max. charging and discharging current (A) | 50 A / 50 A | 50 A / 50 A | 50 A / 50 A | 50 A / 50 A | 50 A / 50 A | 50 A / 50 A | 50 A / 50 A |
| Max. charging and discharging power (kW) | 8 kW | 9,9 kW | 10 kW | 12 kW | 15 kW | 20 kW | 25 kW |
| Battery type | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) | LFP (LiFePO4) |
| DC input data (PV side) | |||||||
| Max. DC input power (kW) | 16 kW | 19,8 kW | 20 kW | 24 kW | 30 kW | 40 kW | 50 kW |
| Max. DC input voltage (Vdc) | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc | 1000 Vdc |
| Start-up voltage (Vdc) | 180 Vdc | 180 Vdc | 180 Vdc | 180 Vdc | 180 Vdc | 180 Vdc | 180 Vdc |
| MPPT voltage range (Vdc) | 150–850 Vdc | 150–850 Vdc | 150–850 Vdc | 150–850 Vdc | 150–850 Vdc | 150–850 Vdc | 150–850 Vdc |
| Rated DC input voltage (Vdc) | 600 Vdc | 600 Vdc | 600 Vdc | 600 Vdc | 600 Vdc | 600 Vdc | 600 Vdc |
| PV input current (A) | 21 A + 21 A | 21 A + 21 A | 21 A + 21 A | 21 A + 21 A | 42 A + 21 A | 42 A + 42 A | 42 A + 42 A |
| Number of MPP trackers / Number of strings per MPP tracker | 2 / 1+1 | 2 / 1+1 | 2 / 1+1 | 2 / 1+1 | 2 / 2+1 | 2 / 2+2 | 2 / 2+2 |
| Grid data | |||||||
| Rated input voltage | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) |
| Rated grid frequency (Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) |
| Max. apparent AC input/output power (kVA) | 8,8 kVA | 9,9 kVA | 11 kVA | 13,2 kVA | 16,5 kVA | 22 kVA | 27,5 kVA |
| Rated AC input/output current (A) [1] | 11,6 A | 14,3 A | 14,5 A | 17,4 A | 21,7 A | 29 A | 36,3 A |
| Max. output current (A) | 12,8 A | 14,3 A | 16 A | 19,2 A | 23,8 A | 32 A | 39,8 A |
| Max. continuous AC throughput (A) | 40 A | 40 A | 40 A | 40 A | 40 A | 80 A | 80 A |
| AC output data (backup power) | |||||||
| Rated output power (kW) | 8 kW | 9,9 kW | 10 kW | 12 kW | 15 kW | 20 kW | 25 kW |
| Max. AC current (A) [2] | 12,8 A | 14,3 A | 16 A | 19,2 A | 23,8 A | 32 A | 39,8 A |
| Peak power (island mode) (kW) | 12 kW (1,5× rated power, 10 s) | 14,9 kW (1,5× rated power, 10 s) | 15 kW (1,5× rated power, 10 s) | 18 kW (1,5× rated power, 10 s) | 22,5 kW (1,5× rated power, 10 s) | 30 kW (1,5× rated power, 10 s) | 37,5 kW (1,5× rated power, 10 s) |
| Rated AC output voltage | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) | 220/380 Vac, 230/400 Vac (-20%~+15%) |
| Rated AC output frequency (Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) | 50/60 Hz (45–55 Hz / 55–65 Hz) |
| Protections | |||||||
| DC reverse polarity protection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| AC output overcurrent protection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| AC output overvoltage protection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| AC output short-circuit protection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Thermal protection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| DC terminal insulation resistance monitoring | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| DC component monitoring | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Residual/ground differential current monitoring | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Arc fault circuit interrupter (AFCI) | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Grid monitoring | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Anti-islanding protection | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
| Ground fault detection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| DC input switch | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Protection against load disconnection during overvoltage | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Residual current detection (RCD) | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| Surge protection level | TYP II (DC), TYP II (AC) | TYP II (DC), TYP II (AC) | TYP II (DC), TYP II (AC) | TYP II (DC), TYP II (AC) | TYP II (DC), TYP II (AC) | TYP II (DC), TYP II (AC) | TYP II (DC), TYP II (AC) |
| General data | |||||||
| Operating temperature range (°C) | -40 to 60 °C (>45 °C power derating) | -40 to 60 °C (>45 °C power derating) | -40 to 60 °C (>45 °C power derating) | -40 to 60 °C (>45 °C power derating) | -40 to 60 °C (>45 °C power derating) | -40 to 60 °C (>45 °C power derating) | -40 to 60 °C (>45 °C power derating) |
| Pollution degree | PD2 (indoor), PD3 (outdoor) | PD2 (indoor), PD3 (outdoor) | PD2 (indoor), PD3 (outdoor) | PD2 (indoor), PD3 (outdoor) | PD2 (indoor), PD3 (outdoor) | PD2 (indoor), PD3 (outdoor) | PD2 (indoor), PD3 (outdoor) |
| Protection class | Class I | Class I | Class I | Class I | Class I | Class I | Class I |
| Voltage classification | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 | DVC B: Grid port, backup power, household, PV, battery. DVC A: Meter, BMS, RS485, DRM, PARA1, PARA2 |
| Protection rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Cooling method | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
| BMS communication | CAN / RS485 | CAN / RS485 | CAN / RS485 | CAN / RS485 | CAN / RS485 | CAN / RS485 | CAN / RS485 |
| Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
| Monitoring module | Wi-Fi | Wi-Fi | Wi-Fi | Wi-Fi | Wi-Fi | Wi-Fi | Wi-Fi |
| Display | LCD + LED | LCD + LED | LCD + LED | LCD + LED | LCD + LED | LCD + LED | LCD + LED |
| Mounting method | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted |
| Warranty | 5 years / 10 years | 5 years / 10 years | 5 years / 10 years | 5 years / 10 years | 5 years / 10 years | 5 years / 10 years | 5 years / 10 years |
| Grid standards | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | NRS 097-2-1, VDE 4105, EN 50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Safety and EMC standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Net weight (kg) | 39,4 kg | 39,4 kg | 39,4 kg | 39,4 kg | 39,4 kg | 39,4 kg | 39,4 kg |
| Gross weight (kg) | 48,6 kg | 48,6 kg | 48,6 kg | 48,6 kg | 48,6 kg | 48,6 kg | 48,6 kg |
| Product dimensions (W × H × D) (mm) | 642 × 445 × 237,5 mm | 642 × 445 × 237,5 mm | 642 × 445 × 237,5 mm | 642 × 445 × 237,5 mm | 642 × 445 × 237,5 mm | 642 × 445 × 237,5 mm | 642 × 445 × 237,5 mm |
| Package dimensions (W × H × D) (mm) | 789 × 568 × 367 mm | 789 × 568 × 367 mm | 789 × 568 × 367 mm | 789 × 568 × 367 mm | 789 × 568 × 367 mm | 789 × 568 × 367 mm | 789 × 568 × 367 mm |
[1], [2] Data based on rated AC voltage 230/400 Vac.
* Detailed warranty conditions can be found in the Felicitysolar manufacturer’s warranty policy.