Inverter – HUAWEI – SUN 2000-3.68KTL-L1 – single-phase – hybrid – HV
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| European efficiency | |
| Weight | 14 kg |
| CN | 85044085 |
Gross
Product details
| Manufacturer | |
|---|---|
| Rated power | |
| Power supply | |
| Hybrid device | |
| Off-grid mode | |
| MPPT | |
| Warranty | |
| Net width | |
| Net depth | |
| Net height | |
| RS485 | |
| SPD Type II | |
| AFCI | |
| MPPT voltage range | |
| Maximum input current per MPPT [A] | |
| European efficiency | |
| Weight | 14 kg |
| CN | 85044085 |
Huawei SUN2000-L1 Smart Energy Center
The Huawei SUN2000-L1 is an advanced hybrid inverter Smart Energy Center designed to maximize solar energy production and integrate with energy storage systems. It offers high efficiency, intelligent energy management features, and dual Maximum Power Point Tracking (MPPT) inputs, delivering optimal energy yield even in challenging conditions. It also includes advanced safety features, including AI-supported arc-fault protection.
Key features of the Huawei SUN2000-L1:
- Maximum efficiency up to 98.4% and weighted European efficiency up to 97.8% ensure efficient conversion of solar energy.
- Two independent MPPT (Maximum Power Point Tracking) inputs allow optimal use of power from two separate strings of PV panels.
- Can integrate with Huawei LUNA2000 batteries (5 kWh–30 kWh) or LG Chem RESU (7H_R/10H_R), enabling a complete energy storage system.
- Advanced AI-supported arc-fault protection significantly enhances the safety of the PV installation.
- Integrated insulation monitoring, DC and AC surge protection (Type II), and RCMU improve safety and reliability.
- Flexible output power ranging from 2000 W to 6000 W (model-dependent) and support for up to 9000 Wp of PV power (with optimizers) adapt to installation needs.
Who is this a good choice for?
The Huawei SUN2000-L1 inverter is an ideal solution for owners of single-family homes and small businesses looking for an efficient and reliable way to generate and store solar energy. It’s well suited for PV installations where maximizing energy yield, ensuring safety, and allowing future integration with an energy storage system are important. It’s a choice for users who value intelligent energy management and modern technology.
| Parameter | SUN2000-2KTL-L1 | SUN2000-3KTL-L1 | SUN2000-3,68KTL-L1 | SUN2000-4KTL-L1 | SUN2000-4,6KTL-L1 | SUN2000-5KTL-L1 | SUN2000-6KTL-L1 |
|---|---|---|---|---|---|---|---|
| Efficiency | |||||||
| Maximum efficiency | 98.2% | 98.3% | 98.4% | 98.4% | 98.4% | 98.4% | 98.4% |
| European weighted efficiency | 96.7% | 97.3% | 97.3% | 97.5% | 97.7% | 97.8% | 97.8% |
| Input (PV) | |||||||
| Recommended maximum PV power | 3000 Wp | 4500 Wp | 5520 Wp | 6000 Wp | 6900 Wp | 7500 Wp | 9000 Wp |
| Maximum input voltage | 600 V | 600 V | 600 V | 600 V | 600 V | 600 V | 600 V |
| Start-up voltage | 100 V | 100 V | 100 V | 100 V | 100 V | 100 V | 100 V |
| MPPT operating voltage range | 90 V–560 V | 90 V–560 V | 90 V–560 V | 90 V–560 V | 90 V–560 V | 90 V–560 V | 90 V–560 V |
| Nominal input voltage | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V |
| Maximum operating current per MPPT | 12.5 A | 18 A | 18 A | 18 A | 18 A | 18 A | 18 A |
| Maximum short-circuit current per MPPT | 12.5 A | 18 A | 18 A | 18 A | 18 A | 18 A | 18 A |
| Number of MPPTs | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Number of inputs | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Input (DC Battery) | |||||||
| Compatible battery | LG Chem RESU 7H_R/10H_R | LG Chem RESU 7H_R/10H_R | LG Chem RESU 7H_R/10H_R | LG Chem RESU 7H_R/10H_R | LG Chem RESU 7H_R/10H_R | LG Chem RESU 7H_R/10H_R | LG Chem RESU 7H_R/10H_R |
| Operating voltage range | 350 – 450 V DC | 350 – 450 V DC | 350 – 450 V DC | 350 – 450 V DC | 350 – 450 V DC | 350 – 450 V DC | 350 – 450 V DC |
| Maximum operating current | 10 A @7H_R / 15 A @10H_R | 10 A @7H_R / 15 A @10H_R | 10 A @7H_R / 15 A @10H_R | 10 A @7H_R / 15 A @10H_R | 10 A @7H_R / 15 A @10H_R | 10 A @7H_R / 15 A @10H_R | 10 A @7H_R / 15 A @10H_R |
| Maximum charging power | 3,500 W @7H_R / 5,000 W @10H_R | 3,500 W @7H_R / 5,000 W @10H_R | 3,500 W @7H_R / 5,000 W @10H_R | 3,500 W @7H_R / 5,000 W @10H_R | 3,500 W @7H_R / 5,000 W @10H_R | 3,500 W @7H_R / 5,000 W @10H_R | 3,500 W @7H_R / 5,000 W @10H_R |
| Maximum discharging power @7H_R | 2200 W | 3300 W | 3300 W | 3500 W | 3500 W | 3500 W | 3500 W |
| Maximum discharging power @10H_R | 2200 W | 3300 W | 3300 W | 3680 W | 4600 W | 5000 W | 6000 W |
| HUAWEI LUNA2000 Energy Storage System | |||||||
| Compatible battery | LUNA2000 5kWh – 30kWh | LUNA2000 5kWh – 30kWh | LUNA2000 5kWh – 30kWh | LUNA2000 5kWh – 30kWh | LUNA2000 5kWh – 30kWh | LUNA2000 5kWh – 30kWh | LUNA2000 5kWh – 30kWh |
| Operating voltage range | 350-560 V DC | 350-560 V DC | 350-560 V DC | 350-560 V DC | 350-560 V DC | 350-560 V DC | 350-560 V DC |
| Maximum operating current | 15 A | 15 A | 15 A | 15 A | 15 A | 15 A | 15 A |
| Maximum charge/discharge power | 5000 W | 5000 W | 5000 W | 5000 W | 5000 W | 5000 W | 5000 W |
| Output | |||||||
| Rated output power | 2000 W | 3000 W | 3680 W | 4000 W | 4600 W | 5000 W | 5000 W |
| Maximum apparent power | 2200 VA | 3300 VA | 3680 VA | 4400 VA | 5000 VA | 5000 VA | 6000 VA |
| Rated output voltage | 220 V/230 V/240 V | 220 V/230 V/240 V | 220 V/230 V/240 V | 220 V/230 V/240 V | 220 V/230 V/240 V | 220 V/230 V/240 V | 220 V/230 V/240 V |
| Rated AC grid frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Maximum output current | 10 A | 15 A | 16 A | 20 A | 23 A | 25 A | 27 A |
| Power factor range | 0.8 leading… 0.8 lagging | 0.8 leading… 0.8 lagging | 0.8 leading… 0.8 lagging | 0.8 leading… 0.8 lagging | 0.8 leading… 0.8 lagging | 0.8 leading… 0.8 lagging | 0.8 leading… 0.8 lagging |
| THD (Total Harmonic Distortion) | ≤3% | ≤3% | ≤3% | ≤3% | ≤3% | ≤3% | ≤3% |
| Additional power interface | Yes (via Backup Box-5000 ¹) | Yes (via Backup Box-5000 ¹) | Yes (via Backup Box-5000 ¹) | Yes (via Backup Box-5000 ¹) | Yes (via Backup Box-5000 ¹) | Yes (via Backup Box-5000 ¹) | Yes (via Backup Box-5000 ¹) |
| Protections | |||||||
| Anti-islanding protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| DC reverse polarity protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Insulation monitoring | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| DC surge protector | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 |
| AC surge protector | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 | Yes, Type II according to EN/IEC 61643-11 |
| Residual current monitoring (RCMU) | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| AC overcurrent protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| AC short-circuit protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| AC surge protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Overheat protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Arc fault protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| General data | |||||||
| Operating temperature range | -25°C ~ +60°C | -25°C ~ +60°C | -25°C ~ +60°C | -25°C ~ +60°C | -25°C ~ +60°C | -25°C ~ +60°C | -25°C ~ +60°C |
| Relative humidity | 0% RH – 100% RH | 0% RH – 100% RH | 0% RH – 100% RH | 0% RH – 100% RH | 0% RH – 100% RH | 0% RH – 100% RH | 0% RH – 100% RH |
| Operating altitude | 0-4000 m | 0-4000 m | 0-4000 m | 0-4000 m | 0-4000 m | 0-4000 m | 0-4000 m |
| Cooling | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection |
| Display | LED indicators | LED indicators | LED indicators | LED indicators | LED indicators | LED indicators | LED indicators |
| Communication | RS485, built-in WLAN module | RS485, built-in WLAN module | RS485, built-in WLAN module | RS485, built-in WLAN module | RS485, built-in WLAN module | RS485, built-in WLAN module | RS485, built-in WLAN module |
| Weight (with mounting bracket) | 12.3 kg | 12.3 kg | 12.3 kg | 12.3 kg | 12.3 kg | 12.3 kg | 12.3 kg |
| Dimensions (with mounting bracket) | 365 x 365 x 140 mm | 365 x 365 x 140 mm | 365 x 365 x 140 mm | 365 x 365 x 140 mm | 365 x 365 x 140 mm | 365 x 365 x 140 mm | 365 x 365 x 140 mm |
| Protection rating | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
| Optimizer compatible with DC MBUS | SUN2000-450W-P | SUN2000-450W-P | SUN2000-450W-P | SUN2000-450W-P | SUN2000-450W-P | SUN2000-450W-P | SUN2000-450W-P |
| Safety | Standards compliance | Standards compliance | Standards compliance | Standards compliance | Standards compliance | Standards compliance | Standards compliance |
| Grid connection standards | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 | EN/IEC 62109-1, EN/IEC 62109-2, G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727 |
*1 Available in Q3 2020. *2 The inverter’s maximum input power is 10,000 Wp when using SUN2000-450W-P power optimizers. *3 The maximum input voltage and the upper limit of the operating voltage will be reduced to 495 V when the inverter is connected to and operating with an LG battery. *4 2500 W for a 5 kWh storage system. *5 AS4777: 4990 W. *6 VDE-AR-N 4105: 4600 VA / AS4777: 4990 VA. *7 AS4777: 4990 VA. *8 AS4777: 21.7 A.