Optimizer TIGO-TS4-A-O-700W
Manufacturer | |
---|---|
Warranty | |
Net width | |
Net depth | |
Net height | |
Cable length | |
Quantity per pallet | |
Quantity per package | |
Maximum efficiency | |
Maximum output current | |
Maximum short-circuit current | |
Mounting method | |
Package weight | |
Application | |
Rated input power | |
Weight | 0,68 kg |
CN | 90308900 |
Product details
Manufacturer | |
---|---|
Warranty | |
Net width | |
Net depth | |
Net height | |
Cable length | |
Quantity per pallet | |
Quantity per package | |
Maximum efficiency | |
Maximum output current | |
Maximum short-circuit current | |
Mounting method | |
Package weight | |
Application | |
Rated input power | |
Weight | 0,68 kg |
CN | 90308900 |
Tigo TS4-A-O Power Optimizer
The Tigo TS4-A-O is an advanced optimization add-on that brings smart module functionality to standard photovoltaic modules, enhancing energy performance and reliability of the system. This innovative solution is perfect for upgrading existing PV installations as well as for deployment in new systems. It complies with UL/NEC requirements for rapid shutdown.
The TS4-A-O add-on supports photovoltaic modules with power outputs of up to 700 W, allowing for flexible applications in a variety of configurations.
Key Features of the Tigo TS4-A-O Optimizer:
- Module-Level Optimization – increases energy yield and provides greater design flexibility, enabling maximization of PV system performance.
- Rapid Shutdown – components compliant with NEC standards, ensuring safety for installations and ease of use.
- Module-Level Monitoring – allows for tracking of energy production and management of the PV system, providing complete control and operational efficiency.
- Easy Installation – quick mounting on standard module frames or using brackets for rack installations, simplifying the integration process with the system.
Who is this a good choice for?
The Tigo TS4-A-O is an excellent solution for installers and owners of photovoltaic systems who want to enhance the performance, safety, and functionality of their PV installations. With its capability for optimization and module-level monitoring, this device is ideal for both upgrading existing systems and new projects requiring advanced technology.
Technical Specification
Parameter | Value |
---|---|
Electrical | |
Maximum Input Voltage (VOC at lowest temperature) | 80V |
Input Voltage Range | 16 – 80V |
Max Input Current (IMP) | 15 A |
Maximum Power | 700W |
Recommended Fuse Current Rating | 20 A |
Cable AWG Size | 12 |
Quick Disconnection Time Limit | ≤30 s |
PVRSE Cables | ≤240 VA, ≤8 A, ≤30 VDC |
Operational Output Power (when connected to an inverter) | |
Maximum Output Current | IDCU MAX |
Maximum Input Voltage | VDCU MAX |
Connections | |
Input Cable Length (from module) | 0.12/0.62 m |
Output Cable Length (to string) | 1.2 m |
Connectors | MC4, EVO2 |
Environmental Parameters | |
UL Operating Temperature Range | -30 – 75°C (-22 – 167°F) |
IEC Operating Temperature Range | -40 – 85°C (-40 – 185°F) |
Storage Temperature Range | -40 – 85°C (-40 – 185°F) |
Outdoor Protection Rating | IP68, NEMA 3R |
Relative Humidity | 0 – 100% |