CN90308900

Tigo TS4-A-O Power Optimizer

The Tigo TS4-A-O is an advanced optimization add-on that brings smart module functionality to standard photovoltaic modules, enhancing energy performance and reliability of the system. This innovative solution is perfect for upgrading existing PV installations as well as for deployment in new systems. It complies with UL/NEC requirements for rapid shutdown.

The TS4-A-O add-on supports photovoltaic modules with power outputs of up to 700 W, allowing for flexible applications in a variety of configurations.

Key Features of the Tigo TS4-A-O Optimizer:

  • Module-Level Optimization – increases energy yield and provides greater design flexibility, enabling maximization of PV system performance.
  • Rapid Shutdown – components compliant with NEC standards, ensuring safety for installations and ease of use.
  • Module-Level Monitoring – allows for tracking of energy production and management of the PV system, providing complete control and operational efficiency.
  • Easy Installation – quick mounting on standard module frames or using brackets for rack installations, simplifying the integration process with the system.

Who is this a good choice for?

The Tigo TS4-A-O is an excellent solution for installers and owners of photovoltaic systems who want to enhance the performance, safety, and functionality of their PV installations. With its capability for optimization and module-level monitoring, this device is ideal for both upgrading existing systems and new projects requiring advanced technology.

Datasheet Optimizer Tigo-TS4-A-O-700W datasheet-optimizer-tigo-ts4-a-o-700w.pdf

Technical Specification

ParameterValue
Electrical
Maximum Input Voltage (VOC at lowest temperature)80V
Input Voltage Range16 – 80V
Max Input Current (IMP)15 A
Maximum Power700W
Recommended Fuse Current Rating20 A
Cable AWG Size12
Quick Disconnection Time Limit≤30 s
PVRSE Cables≤240 VA, ≤8 A, ≤30 VDC
Operational Output Power (when connected to an inverter)
Maximum Output CurrentIDCU MAX
Maximum Input VoltageVDCU MAX
Connections
Input Cable Length (from module)0.12/0.62 m
Output Cable Length (to string)1.2 m
ConnectorsMC4, EVO2
Environmental Parameters
UL Operating Temperature Range-30 – 75°C (-22 – 167°F)
IEC Operating Temperature Range-40 – 85°C (-40 – 185°F)
Storage Temperature Range-40 – 85°C (-40 – 185°F)
Outdoor Protection RatingIP68, NEMA 3R
Relative Humidity0 – 100%

Official distribution